Just a guess, but would it fix the errors if you simply reran the AUDIT command with FIX instead of NOFIX?
Rex -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of esmie moo Sent: Friday, July 18, 2014 10:59 AM To: [email protected] Subject: DFHSM QUESTION - ERR 28 Good Day Gentle Readers, We are in the process of cleaning up the HSM MCDS. I ran an AUDIT DATASETCONTROLS(MIGRATION) NOFIX and the following information was posted : /* ERR 28 VIMSM.PEPA2SX1 - EXTRANEOUS ALIAS RECORD /* FIXCDS A VIMSM.PEPA2SX1.INDEX DELETE /* ERR 28 VIMSM.PEPA2SX1 - EXTRANEOUS ALIAS RECORD /* FIXCDS A VIMSM.PEPA2SX1.KDATA DELETE - END OF - ENHANCED AUDIT - LISTING - I tried to do a HSEND DELETE VIMSM.PEPA2SX1 however I received this error : ARC1001I VIMSM.PEPA2SX1 DELETE FAILED, RC=0002, REAS=0000 ARC1102I DATA SET IS NOT MIGRATED/BACKED UP I tried HSEND DELETE VIMSM.PEPA2SX1.INDEX but I was unsuccessful. ARC1001I VIMSM.PEPA2SX1.INDEX DELETE FAILED, RC=0002, REAS=0000 ARC1102I DATA SET IS NOT MIGRATED/BACKED UP I also tried HSEND FIXCDS D VIMSM.PEPA2SX1 DELETE but it didn't work. ARC0195I TYPE D, KEY VIMSM.PEPA2SX1, FIXCDS DELETE, ERROR=RECORD NOT FOUND ARC1001I FIXCDS D VIMSM.PEPA2SX1 DELETE COMMAND FAILED, RC=0015, REAS=0000 ARC1615I FIXCDS COMMAND REJECTED Could someone suggest something that I could try? The dsn is not cataloged. I looked at the doc. In the Audit Repair Action it says "The unknown record is deleted (internally)" but in the Troubleshooting hints the column is blank. Thanks for your help in advance. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN The information contained in this message is confidential, protected from disclosure and may be legally privileged. If the reader of this message is not the intended recipient or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any disclosure, distribution, copying, or any action taken or action omitted in reliance on it, is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by replying to this message and destroy the material in its entirety, whether in electronic or hard copy format. Thank you. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN