In <[email protected]>, on 06/13/2014
   at 11:11 AM, David Cole <[email protected]> said:

>It turns out the misbehavior I reported was my own fault. I had 
>created my "REFR-only" load module by using a tool (an ancient 
>copy of the PDS command from the "CBT mods tape") to set the 
>following attributes: REFR=1, RENT=0 and REUS=0. It turns out 
>that's an illegal combination that the Binder would never create,

Not that I've ever read, and the last I looked the linkage editor can
still create that combination.
 
-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     ISO position; see <http://patriot.net/~shmuel/resume/brief.html> 
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)

----------------------------------------------------------------------