I forgot to add, show the output. Don't tell us what the output has. Lizette
> -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Lizette Koehler > Sent: Thursday, June 12, 2014 7:39 AM > To: [email protected] > Subject: Re: IODF/HCD query reg DASD > > What version of z/OS? > > > What do you get with > > D M=CHP(xx) > D M=DEV(xxxx) > > Did you IPL or do a soft activate? > > Have you done a TEST Activate? > > > > Lizette > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:[email protected]] > > On Behalf Of P. Mukhopadhyay > > Sent: Thursday, June 12, 2014 7:25 AM > > To: [email protected] > > Subject: IODF/HCD query reg DASD > > > > Hello, > > > > Need help regarding IODF configuration using HCD. > > > > There are two system z hardware in our data center (z9 EC and z10 EC). > > Both of them are connected to same DS8100 storage. The CHPIDs from z9 > > and z10 connect to different storage LCUs in same DS8100. > > > > With the existing z9 CHPIDs (which are already in use) I would like to > > make z10 LCU number 02 DASD devices (already online on z10), visible > > to z9 LPARs. For this, I have added a control unit (type 2107) in the > > z9 IODF with the LCU number 02 and added 256 DASD devices (type 3390). > > > > I have activated (software only) the production IODF on z9, successfully. > > > > However, when I try to vary the devices online on z9, I get an error > > message: > > IEE025I UNIT XXXX HAS NO LOGICAL PATHS > > > > I have executed /d m=chp(nn) commands with all the CHPIDs in use on > > z9, but the output does not show the DASD device range that I have added > through the IODF. > > > > Next, I have executed DEVSERV PATH command as follows: > > /DS P,XXXX where XXXX is the device number > > > > > > The command output shows UCB NOT CONNECTED, PATH STATUS > UNAVAILABLE > > > > IEE459I 18.05.40 DEVSERV PATHS 220 > > UNIT DTYPE M CNT VOLSER CHPID=PATH STATUS > > RTYPE SSID CFW TC DFW PIN DC-STATE CCA DDC CYL CU- > TYPE > > 0XXXX,3390 ,F,000, ,UCB NOT CONNECTED, PATH STATUS > > UNAVAILABLE > > ************************ SYMBOL DEFINITIONS ************************ F > > = OFFLINE > > > > > > > > I have tried this in two different ways by: > > > > 1. using same CU and device names on z9 as well as z10. e.g. the CU is > > called > > D100 on both z9 and z10 and the devices are called D100 to D1FF > > > > 2. using different CU/device names. e.g. on z10 CU is called B100 and > > devices are called B100 to B1FF whereas on z9 the CU was named A100 > > and devices A100 to A1FF. > > > > Neither of these worked :( > > > > > > I am not sure if I am missing anything here. Any pointer/suggestion to > > make the device visible will be highly appreciated. > > > > Thanks, > > P. Mukhopadhyay > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN