I forgot to add, show the output. Don't tell us what the output has.

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Lizette Koehler
> Sent: Thursday, June 12, 2014 7:39 AM
> To: [email protected]
> Subject: Re: IODF/HCD query reg DASD
> 
> What version of z/OS?
> 
> 
> What do you get with
> 
> D M=CHP(xx)
> D M=DEV(xxxx)
> 
> Did you IPL or do a soft activate?
> 
> Have you done a TEST Activate?
> 
> 
> 
> Lizette
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of P. Mukhopadhyay
> > Sent: Thursday, June 12, 2014 7:25 AM
> > To: [email protected]
> > Subject: IODF/HCD query reg DASD
> >
> > Hello,
> >
> > Need help regarding IODF configuration using HCD.
> >
> > There are two system z hardware in our data center (z9 EC and z10 EC).
> > Both of them are connected to same DS8100 storage. The CHPIDs from z9
> > and z10 connect to different storage LCUs in same DS8100.
> >
> > With the existing z9 CHPIDs (which are already in use) I would like to
> > make z10 LCU number 02 DASD devices (already online on z10), visible
> > to z9 LPARs. For this, I have added a control unit (type 2107) in the
> > z9 IODF with the LCU number 02 and added 256 DASD devices (type 3390).
> >
> > I have activated (software only) the production IODF on z9, successfully.
> >
> > However, when I try to vary the devices online on z9, I get an error 
> > message:
> > IEE025I UNIT XXXX     HAS NO LOGICAL  PATHS
> >
> > I have executed /d m=chp(nn) commands with all the CHPIDs in use on
> > z9, but the output does not show the DASD device range that I have added
> through the IODF.
> >
> > Next, I have executed DEVSERV PATH command as follows:
> > /DS P,XXXX            where XXXX is the device number
> >
> >
> > The command output shows UCB NOT CONNECTED, PATH STATUS
> UNAVAILABLE
> >
> > IEE459I 18.05.40 DEVSERV PATHS 220
> >  UNIT DTYPE  M CNT VOLSER  CHPID=PATH STATUS
> >       RTYPE  SSID CFW TC   DFW PIN DC-STATE CCA DDC       CYL CU-
> TYPE
> > 0XXXX,3390  ,F,000,      ,UCB NOT CONNECTED, PATH STATUS
> > UNAVAILABLE
> > ************************ SYMBOL DEFINITIONS ************************ F
> > = OFFLINE
> >
> >
> >
> > I have tried this in two different ways by:
> >
> > 1. using same CU and device names on z9 as well as z10. e.g. the CU is
> > called
> > D100 on both z9 and z10 and the devices are called D100 to D1FF
> >
> > 2. using different CU/device names. e.g. on z10 CU is called B100 and
> > devices are called B100 to B1FF whereas on z9 the CU was named A100
> > and devices A100 to A1FF.
> >
> > Neither of these worked :(
> >
> >
> > I am not sure if I am missing anything here. Any pointer/suggestion to
> > make the device visible will be highly appreciated.
> >
> > Thanks,
> > P. Mukhopadhyay
> >

----------------------------------------------------------------------