yes, Mark. I already check. SYS1.CAPC.DAE dataset mentioned in ADYSET00
parmlib member is in good shape . But not sure why still we getting this
issue.


/d DUMP
 IEE852I 04.54.10 SYS1.DUMP STATUS 960
 SYS1.DUMP DATA SETS AVAILABLE=000 AND FULL=000
 CAPTURED DUMPS=0000, SPACE USED=00000000M, SPACE FREE=00000500M
 AUTOMATIC ALLOCATION IS: ACTIVE
    NO SMS CLASSES DEFINED
    AVAILABLE DASD VOLUMES: RES001
    NAME=SYS1.DUMP.D&YYMMDD..T&HHMMSS..&SYSNAME..S&SEQ.
       EXAMPLE=SYS1.DUMP.D140609.T115410.MVS00.S00000


On Mon, Jun 9, 2014 at 5:26 PM, Mark Jacobs <[email protected]>
wrote:

> On 06/09/14 07:52, venkat kulkarni wrote:
>
>> Hello,
>>            I am suddenly getting below error on one of my SYSPLEX system.
>>
>> IEA651E SYSPLEX DUMP DIRECTORY PREOCESS TERMINATED.
>>
>> there is no associated message with this. I check the DUMPSRV  address
>> space and this is also working. But I am not able to identify that how to
>> check for current status of SYSPLEX dump dataset to take necessary action.
>>
>>
> Make sure that the dataset that you specified in parmlib member ADYSETxx
> is in good shape.
>
> --
> Mark Jacobs
> Time Customer Service
> Tampa, FL
> ----
>
> The quiet ones are the ones that change the universe...
> The loud ones only take the credit.
>
> Londo Mollari - Babylon 5
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to