The SMF SST control block is not a GUPI nor is documented anywhere that I am aware of.
The code in SHOWZOS is using either reverse-engineered DSECTs or something left over from the pre-OCO days. > On 24 Apr 2014, at 17:40, "Charles Mills" <[email protected]> wrote: > > It is indeed there: > > SYS > TYPE(0,4-7,14-15,18,21,26,30,36,41-42,50,60-90,94,100-103,109-116,118-20 > > EXITS(IEFU29,IEFUTL,IEFUJI,IEFUSO,IEFUJP,IEFUSI,IEFUJV,IEFACTRT,IEFU85,I > > > OMVS > TYPE(0,4-7,14-15,18,21,26,30,36,41-42,50,60-90,94,100-103,109-116,118-20 > EXITS(IEFU85,IEFU84,IEFU83) > > > > STC TYPE(0,30,41-42,50,60-83,88-89,100-103,109-110,115-120) > etc. > > Somewhere around line 8250 of SHOWZOS Gilbert pulls it (not surprisingly) > out of the SMCA and associated tables. SSTEXTAB. > > Anyone know where the SMF Selection Control Table is documented? I don't see > it in my MVS Data Areas, but I suppose I am looking in the wrong place. > > > Charles > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Charles Mills > Sent: Thursday, April 24, 2014 11:26 AM > To: [email protected] > Subject: Re: Any way to programmatically determine state of SMFPRMxx > SYS(EXITS())? > > Excellent thought. I shall look into that. Thanks, > > Charles > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Miklos Szigetvari > Sent: Thursday, April 24, 2014 11:06 AM > To: [email protected] > Subject: Re: Any way to programmatically determine state of SMFPRMxx > SYS(EXITS())? > > ShowMvs can so I think you can also (source is available for ShowMvs) > >> On 24.04.2014 16:42, Charles Mills wrote: >> Is there any way for an (authorized) program to determine whether >> SYS(EXITS(IEFU8n)) has been specified? That is, whether IEFU8n (where >> 'n' is 3, 4 or 5) is active. >> >> Note that z/OS allows a module to be added to an exit even though the >> exit is not active and the module will never receive a single call. I >> am looking for whether the EXIT is active and will be called by z/OS, >> not whether or not module XXXXX has been installed on the exit. >> >> I am hoping for a conventional z/OS macro type answer, not "issue /D >> SMF,O from Rexx and parse the results." >> >> I am looking at bit EXAAEDEFINED in the CSVDYNEX answer area mapping >> DSECT CSVEXAA. Does this provide the information I am looking for? >> Does something else? > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email > to [email protected] with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN