At some point in your SMPE process, HOLDDATA must reside in an ordinary 
MVS/DFP file in EBCDIC. I.e. the file that you input to SMPE RECEIVE must 
be readable. Check the contents of that file. 

Only full.text contains FIXCAT data. Other (smaller) files contain ++HOLD 
but not FIXCAT. 

.
.
JO.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]



From:   "Dazzo, Matt" <[email protected]>
To:     [email protected], 
Date:   12/02/2013 12:29 PM
Subject:        Re: Missing Fix Report Question
Sent by:        IBM Mainframe Discussion List <[email protected]>



I believe Kurt's theory would be closest to what actually happened. I did 
pull only 1yr of hold data before running the missing fix report. Then 
when pulling down the 1st batch of ptf's I specified the specific ptf's 
plus pre and corecs. Is there a way to determine when I pulled down the 
second set of PTF's what hold data came down with it? The hold data is in 
a unix file and is unreadable when browsing.

Thanks Matt

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On 
Behalf Of Kurt Quackenbush
Sent: Monday, December 02, 2013 10:50 AM
To: [email protected]
Subject: Re: Missing Fix Report Question

Here's my theory:  You said you "pulled down 1yr of hold data".  Only 
the 2 year HOLDDATA file contains Fix Category HOLDs, therefore, the 
first report you ran didn't use the latest Fix Category HOLDs.  You then 
"pulled down and applied" the missing PTFs and reran the report, being 
surprised to find new missing PTFs.  How did you obtain the PTFs?  Most 
likely the 2 year HOLDDATA file was delivered with those PTFs, which 
contains Fix Category HOLDs.  When you reran the report, you were 
finally using the latest and greatest HOLDs, hence the additional 
entries in the report.

Kurt Quackenbush -- IBM, SMP/E Development



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to