I think the OP stated that his code could hold locks - in which case the latch 
services cannot be used.

Rob Scott
Lead Developer
Rocket Software
77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA
Tel: +1.781.684.2305
Email: [email protected]
Web: www.rocketsoftware.com

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Jon Perryman
Sent: 02 November 2013 19:30
To: [email protected]
Subject: Re: Serialization without Enque

As a last resort, a GRS latch could be used.

Jon Perryman.



>________________________________
> From: Tony Harminc <[email protected]>
>
>
>
>On 1 November 2013 16:22, Donald Likens <[email protected]> wrote:
>> I have a situation where I need to serialize processing and cannot 
>> use CDS because the two addresses being updated cannot be next to each other 
>> (because I use CDS with these two addresses with other addresses).
>
>CDSG, perhaps?
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to