You need to eliminate the dropsym if it does not exist:

address IPCS
"EVALSYM XXXX"
if rc = 0 then
     "DROPSYM XXXX"

Jon Perryman



>________________________________
> From: "Hardee, Chuck" <[email protected]>
>To: [email protected] 
>Sent: Thursday, October 17, 2013 11:23 AM
>Subject: An IPCS question
> 
>
>Hello Everyone,
>
>I have a REXX in which I have coded various commands that I do every time I 
>have to look at a dump.
>In those commands is a DROPSYM statement, in fact, several of them.
>
>What I would like to do is eliminate the message:
>
>BLS18064I No symbols found
>
>that is produced by the DROPSYM command.
>
>I have NOSUMMARY coded on the DROPSYM but that doesn't do it.
>Anyone else tired this and succeeded?
>If so, willing to share the knowledge?
>
>Thanks,
>Chuck
>
>Charles (Chuck) Hardee
>Senior Systems Engineer/Database Administration
>CCG Information Technology
>Thermo Fisher Scientific
>300 Industry Drive
>Pittsburgh, PA 15275
>Direct: 724-517-2633
>FAX: 412-490-9230
>[email protected]
>
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to [email protected] with the message: INFO IBM-MAIN
>
>
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN