Andrew, If you have RLS in place (Record Level Sharing), that will be lost on a COLD start. So, just have the information available when you IPL from a D SMS,SMSVSAM,ALL command.
You will need it to put it back. Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Andrew Metcalfe > Sent: Thursday, October 17, 2013 6:51 AM > To: [email protected] > Subject: Re: Possible To Remove Both CFRM Couple datasets? > > Barbara > > Definitely no CFRM policy active - D XCF tells me so. > I did suspect that I would need to do a cold (newly formatted Sysplex CDS) sysplex- > wide IPL. It's only a infrastructure (SDM) sysplex so it shouldn't be that big a deal to > correct it. > > Thanks > > Andrew > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of [email protected] > Sent: 17 October 2013 14:14 > To: [email protected] > Subject: Re: Possible To Remove Both CFRM Couple datasets? > > > We have (by oversight) an active base sysplex with CFRM couple datasets > defined in COUPLExx. As it is a base sysplex there is obviously no active CFRM > policy. > Are you sure you don't have an active CFRM policy? The policy that was last active > on those CFRM CDSs would have been activated, no matter if the CFs defined to it > are there or not. > > You could try setxcf stop,policy,type=cfrm > > (caution - I have never tried it before). > > > Is there any way to remove the CFRM dataset definitions from the running > sysplex without a sysplex-wide IPL to re-drive COUPLExx once the definitions have > been removed? > Not that I know. Even worse, even if you do a sysplex-wide IPL and have the > CFRM CDSs physically deleted (so they're not there anymore) and removed from > COUPLExx a D XCF will still show them as defined/active/available (*there*) > because that information is kept in the sysplex CDS. At least this was the way it > worked about 10 years ago when I tried to get rid of the unused CDSs in the D XCF > display. I haven't deliberately retested it. Back then, I could only get rid of those > displays by doing a sysplex wide true cold start with a freshly formatted sysplex > CDSs. At about the same time I lost any awe I may have had at the prospect of a > sysplex wide cold start. > > Barbara > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email to > [email protected] with the message: INFO IBM-MAIN This e-mail and any > attachments are confidential and intended solely for the addressee and may also be > privileged or exempt from disclosure under applicable law. If you are not the > addressee, or have received this e-mail in error, please notify the sender > immediately, delete it from your system and do not copy, disclose or otherwise act > upon any part of this e-mail or its attachments. > > Internet communications are not guaranteed to be secure or virus-free. > The Barclays Group does not accept responsibility for any loss arising from > unauthorised access to, or interference with, any Internet communications by any > third party, or from the transmission of any viruses. Replies to this e-mail may be > monitored by the Barclays Group for operational or business reasons. > > Any opinion or other information in this e-mail or its attachments that does not relate > to the business of the Barclays Group is personal to the sender and is not given or > endorsed by the Barclays Group. > > Barclays Bank PLC. Registered in England and Wales (registered no. > 1026167). > Registered Office: 1 Churchill Place, London, E14 5HP, United Kingdom. > > Barclays Bank PLC is authorised by the Prudential Regulation Authority and > regulated by the Financial Conduct Authority and the Prudential Regulation Authority > (Financial Services Register No. > 122702). > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email to > [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN