My general recommendation is to have separate location counters for code and 
data. Only set up addressability for the data LOCTR.

-- 
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3
עַם יִשְׂרָאֵל חַי
נֵ֣צַח יִשְׂרָאֵ֔ל לֹ֥א יְשַׁקֵּ֖ר




________________________________________
From: IBM Mainframe Discussion List <[email protected]> on behalf of 
Paul Gilmartin <[email protected]>
Sent: Sunday, August 17, 2025 1:14 PM
To: [email protected] <[email protected]>
Subject: Re: RMODE 64


External Message: Use Caution


On Sun, 17 Aug 2025 12:10:56 -0400, Joseph Reichman  wrote:

>Right that’s what I saw so in order to establish addressable you would do
>
>LARL    RX,CSECTNAME right
>
But if relative addressing is available you
have less need for that base register.

--
gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN




----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to