Thank Gaid for response. It is Fiber connection.
Thank you, Prashant -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of גדי בן אבי Sent: 13 July 2025 13:21 To: [email protected] Subject: [EXTERNAL] Re: OSA physical connectivity check If it's a copper connection, you could connect a PC instead of the OSA and see if it connects to the switch. For all connections there are devices that will tell you if the cable is connected. Gadi ________________________________ From: IBM Mainframe Discussion List <[email protected]> on behalf of Prashant Joshi <[email protected]> Sent: Sunday, July 13, 2025 09:19 To: [email protected] <[email protected]> Subject: OSA physical connectivity check Hello, Is there any way to verify physical connectivity between OSA card and network switch? This is for new Lpar (not yet IPLed) and new OSA card. Switch side connection shows no signal due to no TCPIP at Lpar side. Is there any way to verify physical connection, without IPLing the Lpar? Thank you, Prashant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN