Jumping late into this thread, I would like to add some suggestions:

- the RENT option is specified as a compiler options, which is used to create artificial reentrancy on programs which are otherwise non-reentrant, which involves the allocation of static variables in a dynamic area called WSA (writable static area). This area must then be initialized on first call. This is what COULD BE accomplished by a call to IGZ@SCH4 and IGZXMCPY (the latter shold be MEMCPY).

So I would look if there are static variables which need initialization in the first of the two modules, and then try to find out if this initialization is really needed OR if the variables could be converted to automatic (or: if the RENT option is really needed, and what happens if it is changed to NORENT).

This is still a wild guess ... to analyze this, I would need access to the complete sources involved (and the compile and binder listings).

HTH, kind regards

Bernd


Am 23.05.2025 um 10:52 schrieb Ravikumar Srinivasan:
Hi Experts,

Thank you so much for all your replies!!!

The WS-PGMA do NOT have INITIAL coded in it.

Compiler listing of WS-PGMA of shows there are only 4 BLL cells used in WS-PGMA

Both WS-PGMA and WS-PGMB are compiled using "IBM Enterprise COBOL for z/OS  
6.2.0".
I compared the compiler options of the both the programs. There is no 
difference.
Below is the compiler options taken from the compiler listing.

Options in effect:
  NOADATA
  NOADV
    AFP(NOVOLATILE)
    APOST
    ARCH(12)
    ARITH(COMPAT)
  NOAWO
  NOBLOCK0
    BUFSIZE(24576)
  NOCICS
    CODEPAGE(1140)
  NOCOMPILE(S)
  NOCOPYLOC
  NOCOPYRIGHT
  NOCURRENCY
    DATA(31)
  NODBCS
  NODECK
  NODEFINE
NODIAGTRUNC
   DISPSIGN(COMPAT)
NODLL
NODUMP
NODYNAM
NOEXIT
NOEXPORTALL
NOFASTSRT
   FLAG(W)
NOFLAGSTD
   HGPR(PRESERVE)
NOINITCHECK
NOINITIAL
   INLINE
   INTDATE(ANSI)
   LANGUAGE(EN)
   LINECOUNT(60)
NOLIST
   MAP(HEX)
   MAXPCF(100000)
NOMDECK
NONAME
   NSYMBOL(DBCS)
NONUMBER
NONUMCHECK
   NUMPROC(NOPFD)
   OBJECT
   OFFSET
   OPTIMIZE(1)
   OUTDD(SYSOUT)
NOPARMCHECK
   PGMNAME(COMPAT)
   QUALIFY(COMPAT)
   RENT
   RMODE(AUTO)
NORULES
NOSERVICE
NOSEQUENCE
   SOURCE
   SPACE(1)
NOSQL
   SQLCCSID
NOSQLIMS
NOSSRANGE
NOSTGOPT
   SUPPRESS
NOTERM
   TEST(NOEJPD,DWARF,SOURCE,NOSEPARATE)
NOTHREAD
   TRUNC(STD)
NOVBREF
   VLR(COMPAT)
   VSAMOPENFS(COMPAT)
NOWORD
   XMLPARSE(XMLSS)
   XREF(FULL)
   ZONEDATA(PFD)
   ZWB

As Ralph mentioned I expanded the C08 report. CSECTs IGZ@SCH4, IGZXMCPY from 
IGZXLPKA is invoked during the call to WS-PGMA, but not for WS-PGMB.
C08: CPU Usage Referred Attribution
-------------------------------------
Name Description Percent of CPU Time * 10.00% ±0.8%
                                        
*....1....2....3....4....5....6....7....8
  Z0XX0XXK  Application Program    12.89
  ± Z0XX0XXK  CSECT in Z0XX0XXK    12.89
    ± 002548    Attribution Offset  9.24   - CALL TO WS-PGMA
                in Z0XX0XXK
      ± IGZXLPKA  COBOL Module      9.23
        ± IGZ@SCH4  COBOL Module    6.80
        ± IGZXMCPY  COBOL Module    2.34
        ± IGZXFCA4  COBOL Module    0.08
      ± 00000000_0001Bxxx Unresolv  0.00

    ± 00248C    Attribution Offset  0.11   - CALL TO WS-PGMB
                in Z0XX0XXK
      ± IGZXLPKA  COBOL Module      0.11
        ± IGZXFCA4  COBOL Module    0.06
        ± IGZXFCAL  COBOL Module    0.04

I tried to google IGZ@SCH4 and IGZXMCPY. I could not find any information on 
them

Thanks,