I did it about month ago:
1. stop tcpip
2. SET OMVS=01
BPXPRM01 where I have INET commented out and these options for CINET:
  FILESYSTYPE TYPE(CINET) ENTRYPOINT(BPXTCINT)
   NETWORK DOMAINNAME(AF_INET)
DOMAINNUMBER(2)
MAXSOCKETS(64000)
TYPE(CINET)
INADDRANYPORT(2000)
INADDRANYCOUNT(325)

   SUBFILESYSTYPE NAME(TCPIP)         /* Name of file system         */
                TYPE(CINET)           /* Type matching Cinet's TYPE  */
            ENTRYPOINT(EZBPFINI)      /* Entry point of load module  */
                DEFAULT               /* <- The Default Socket PFS   */

   SUBFILESYSTYPE NAME(TCPIP322)      /* Name of file system         */
                  TYPE(CINET)         /* Type matching Cinet's TYPE  */
              ENTRYPOINT(EZBPFINI)    /* Entry point of load module  */
3. start TCPIP
4. start TCPIP322

Useful commands:
D OMVS,P
D OMVS,CI=ALL
DISPLAY OMVS,PFS

HTH.

Pozdrawiam/Best regards,

Rafal Hanzel
Programista systemowy, Dzia? Badan' i Rozwoju Systemów Komputerowych
Tel. +48 32 3589246, Fax +48 32 3589277, email: [email protected]
Tel. kom. +48 501677656
Zak?ad Elektronicznej Techniki Obliczeniowej w Katowicach Spó?ka z o.o.
40-158 Katowice, ul. Owocowa 1
Sa;d Rejonowy Katowice - Wschód w Katowicach Wydzia? VIII Gospodarczy Krajowego 
Rejestru Sa;dowego, KRS 0000051477
Kapita? zak?adowy: 264500 z?
NIP 634-013-11-06
http://www.zetokatowice.pl

Jestes'my uczestnikiem Programu
RZETELNA Firma
Sprawdz' nasza; rzetelnos'c' na
http://www.rzetelnafirma.pl/8FGKEVFH

Tres'c' tej informacji moz.e byc' poufna, w zwia;zku z czym powinna trafic' 
bezpos'rednio do ra;k adresata. Jakiekolwiek jej ujawnianie, rozpowszechnianie, 
ba;dz' kopiowanie jest zabronione. W przypadku omy?kowego otrzymania niniejszej 
informacji prosimy o poinformowanie nadawcy i usunie;cie jej z komputera.

W dniu 2013-06-04 22:04, Gibney, Dave pisze:
You need to use CINET instead of INET. I did it years ago w/IPL. No idea if it 
can be done dynamically, but I doubt it.

Dave Gibney
Information Technology Services
Washington State University


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]]
On Behalf Of Jim McAlpine
Sent: Tuesday, June 04, 2013 4:33 AM
To: [email protected]
Subject: second TCPIP stack

I want to set up a second TCPIP stack to do some testing.  I have the
following coded in BPXPRMxx.

FILESYSTYPE TYPE(INET) ENTRYPOINT(EZBPFINI)

SUBFILESYSTYPE NAME(TCPIP)
        TYPE(INET)
        ENTRYPOINT(EZBPFINI)

NETWORK DOMAINNAME(AF_INET)
         DOMAINNUMBER(2)
         MAXSOCKETS(30000)
         TYPE(INET)
         INADDRANYPORT(5555)
         INADDRANYCOUNT(1000)

NETWORK DOMAINNAME(AF_UNIX)
         DOMAINNUMBER(1)
         MAXSOCKETS(2000)
         TYPE(UDS)
Apart from setting up the additional STC's etc, is it just a case of adding
  something like this -

SUBFILESYSTYPE NAME(TCPIP2)
        TYPE(INET)
        ENTRYPOINT(EZBPFINI)

to allow a second instance to start up.  Second question, can this be done
dynamically.

Jim McAlpine

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to