Hi Gil,
Please see PDSLOAD (CBT File 093).
Regards,
David
On 2024-04-14 09:04, Paul Gilmartin wrote:
On Sat, 13 Apr 2024 20:01:50 -0500, Mike Schwab wrote:
You can set it up for a //SYSIN DD DATA,DLM='??' and add the
'??'
Card at the end.
That's not enough. If the input PDS contains a member with a line
beginning with "./", which is likely in JCL with instream data,
IEBUPDTE will improperly treat it as a command, not data.
A similar problem arises if a data line begins with "??".
And no DLM is safe to use with instream XMIT output.
On Sat, Apr 13, 2024 at 6:52 PM Paul Gilmartin wrote:
On Sun, 14 Apr 2024 08:34:30 +1000, Wayne Bickerdike wrote:
I have some REXX code that extracts all members of a PDS and writes it to a
sequential file. Each member extracted is prefixed with the ./ADD card with
the original member name. Handy for moving a PDS to another system.
IEBUPDTE was the utility of choice when all we had was a card punch and
card reader. (1975).
Have you just rediscovered IEBPTPCH?
How does this work if your input PDS is a JCL library containing some
jobs with IEBUPDTE steps with instream commands?
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN