Gil wrote:
>I'm ignorant, or at best outdated. I haven't known of use of symbols by SMP/E.
>But are there instances where the same &symbol would need to appear in
>one instream data set where it should be evaluated and in another where it
>must not, regardless of //name DD DATA,SYMBOLS=...? Cite detailed
>example, please.
I mean things like the RFPREFIX value on a RECEIVE command, which apparently
cannot be &whatever but must specify the data set prefix of the RELFILEs. Same
for the value for a PATH on a DDDEF.
>There are ways. however cumbersome, to escape symbol evaluation in
>instream data sets.
Well, maybe; I didn't write this stuff but the guy who did was pretty sharp,
and couldn't figure out ways around the above. He also noted this:
//* ***NOTE*** Some references to variable values are in records
//* provided as part of SYSIN DD *, and thus cannot be
//* filled in using JCL variables (&HLQ et al.). Thus
//* in this job, you must replace all references to
//* !hlq!, !unit!, and !volser!, not just the single
//* SET statement for each.
Maybe there's a clever way around that? It's referring to things like:
//SYSIN DD *
DEFINE CLUSTER( +
NAME(!hlq!.GLOBAL.CSI) +
VOLUMES(!volser!) +
CYLINDERS(20 10) +
FREESPACE(2 2) +
KEYS(24 0) +
RECORDSIZE(24 143) +
SHAREOPTIONS(2 3) +
) +
DATA ( +
NAME(!hlq!.GLOBAL.CSI.DATA) +
CONTROLINTERVALSIZE(8192) +
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,