I've always heard that JES2 was done half ASP.



Sent with Proton Mail secure email.

------- Original Message -------
On Friday, May 12th, 2023 at 9:03 AM, Paul Gilmartin 
<0000042bfe9c879d-dmarc-requ...@listserv.ua.edu> wrote:


> On Fri, 12 May 2023 02:11:03 -0700, Ed Jaffe wrote:
> 
> > ...
> > I would try coding SYMBOLS=EXECSYS just like you would with a normal
> > batch job. If it doesn't work as expected, it might be an APARable
> > behavior...
> 
> When is the value of a dynamic system symbol fixed:
> o At job step initiation?
> o At SYSIN OPEN?
> o Record-by-record as the SYSIN is read?
> 
> If the last, might the same symbols have different values in different records
> of the same SYSIN, or two different symbols have anachronistic behavior?
> 
> --
> gil
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to