Issue a D SYMBOLS. You should have &SYSDATE and &SYSTEM available. Check the 
Init & Tuning Guide/Reference for "static system symbols".
If not, there are a number of programs on the CBT tape to perform symbol 
substitution @ submission time.

HTH,

Al Staller | Z Systems Programmer | KBM Group | (Tel) 972 664-3565 | 
[email protected]


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Lizette Koehler
Sent: Friday, April 26, 2013 1:53 PM
To: [email protected]
Subject: JCL statements and symbolics - Dates

z/OS V1.12

I have a need to have JCL (Not STC) coded with date and possibly time.  The 
requirement is to NOT use a GDG

So is it possible to code

//DD1  DD DSN= HLQ.D&Date..T&Time..LLQ


Are there symbolics in the z/OS V1.12 system that is available to the batch JCL 
during conversion?  

I am not looking to create a REXX or CLIST to submit the job to put in the date 
and time.  Just basic JCL process.

I have been reading the JCL Reference it seems that only STC JCL has this 
functions.  Not Batch JCL

Thanks for any commentary


Lizette

----------------------------------------------------------------------