The DASD service times calculated by SYSVIEW do not use the WLM control blocks.
SYSVIEW uses the data found in the EMCB control blocks.
The times and counts shown in SYSVIEW can be viewed in real-time over the last 
hour in 1 minute intervals.
Within SYSVIEW, you can view this information using the following commands:

1. DASDRESP - SYSVIEW collected information
2. RMDASD - RMF information

The data shown in each will be very similar. The difference will be based on 
the timing of the collection.

Todd J. Gagle
Distinguished Engineer, Broadcom Software

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN