The simple solution is to split the single job into multiple jobs.  As a start, 
put the first 250 into JOB1, the second 250 into JOB2 and the last 250 into 
JOB3.

It means 3 passes of the input file instead of one, but the jobs will run and 
you will get the result you need.

HTH

Peter

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Ron 
Thomas
Sent: Saturday, June 11, 2022 12:14 AM
To: [email protected]
Subject: dfsort -TASK I/O TABLE EXCEEDS TIOT LIMIT OF 0064K

Hello -

We are splitting a very large files in to 750 files dynamically based on key , 
which means if the key changes the file is moved to the respective ones


we are getting the message 

STEPBB - TASK I/O TABLE EXCEEDS TIOT LIMIT OF 0064K STEPBB - STEP WAS NOT 
EXECUTED.

and hence the step is not getting executed .

File LRECL = 500 Key is from position 19,4.

Here is the control card used

SORT FIELDS=COPY
OUTREC IFTHEN=(WHEN=GROUP,KEYBEGIN=(19,4),PUSH=(501:ID=3))
OUTFIL FNAMES=OUT001,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,001)
OUTFIL FNAMES=OUT002,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,002)
OUTFIL FNAMES=OUT003,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,003)
OUTFIL FNAMES=OUT004,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,004)
OUTFIL FNAMES=OUT005,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,005)
OUTFIL FNAMES=OUT006,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,006)
OUTFIL FNAMES=OUT007,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,007)
OUTFIL FNAMES=OUT008,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,008)
---
--
OUTFIL FNAMES=OUT749,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,749)
OUTFIL FNAMES=OUT750,BUILD=(1,500),INCLUDE=(501,3,ZD,EQ,750)


so could some let me know how to get this fixed ? of is there any other way we 
can build this one ?


Regards
Ron T
--

This message and any attachments are intended only for the use of the addressee 
and may contain information that is privileged and confidential. If the reader 
of the message is not the intended recipient or an authorized representative of 
the intended recipient, you are hereby notified that any dissemination of this 
communication is strictly prohibited. If you have received this communication 
in error, please notify us immediately by e-mail and delete the message and any 
attachments from your system.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to