Just another though, you said it was working good, usually if I'm not mistaking those processes start before any security system, if stopped or canceled and now started when ACF2 is UP and never defined to your security package you will get this same error, I've seen the same with processes lien LLA, DLF to mention a few

Carmen


On 3/23/2022 1:17 PM, Carmen Vitullo wrote:
it's been a long time since I've worked with ACF2, so maybe the terminology ACF2 uses is confusing ACF2, TSS and RACF  require an ID, not to much a LOGONID but IIRC those OMVS processes should all be running under the OMVS OWNER of BPXOINIT, maybe there's a mis-configuration or someone removed SYSLOGD from the list of processes that run (get initialized) under the OMVS address space - just a thought

Carmen

On 3/23/2022 10:54 AM, SUBSCRIBE IBM-MAIN Srinivas Aeturi wrote:
Hi Everyone,

We are running on z/OS 2.2.  And we have configured SYSLOGD and it was running good. But now, The SYSLOGD ID is not existing and task SYSLOGD  is not running. And we are getting below error when we try to start it. I see no one deleted SYSLOGD ID. But still, unable to figure out the issue what caused SYSLOGD ID to not present in the system. Did anyone experience this problem earlier.

ACF01004 LOGONID SYSLOGD NOT FOUND
IEF170I 1 SYSLOGD  ACF01004 LOGONID SYSLOGD NOT FOUND
IEE296I SYSLOGD  FAILED BY SECURITY INTERFACE.  RC=00000004 RSN=00000000 SAFRC=00000008

Thanks
Srinivas

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email [email protected]  with the message: INFO IBM-MAIN


--
/I am not bound to win, but I am bound to be true. I am not bound to succeed, but I am bound to live by the light that I have. I must stand with anybody that stands right, and stand with him while he is right, and part with him when he goes wrong. *Abraham Lincoln*/

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to