On Mon, 6 Dec 2021 15:13:50 -0500, Steve Smith wrote:

>Well, as most machine-CC operates after the line is printed, and ASA-CC
>operates before, I'd think it would be more complicated than that.
>
Oops!  I forgot.  Now that you remind me, I recall that CMS (used to)
issue 3 commands for each ASA-CC line:
    SKIP/SPACE IMMEDIATE
    PRINT NOSPACE
    NOP

CP, starting perhaps, ad VM/XA came to optimize that, collapsing into one 
command.

-- gil

----------------------------------------------------------------------