I agree with Charles. This is probably a firewall issue on the client side. Have their network guys check the logs to see what's going on. If it works for you, it should also work for the client. When I've seen these before, and we see a lot of this, 99 times out of 100, it's the client's firewall blocking the connection. You can get all sorts of messages as processing continues by ftp. They probably need to whitelist you on their side as a "safe" connection partner.
Ramsey On Wed, Nov 17, 2021 at 12:59 PM Charles Mills <[email protected]> wrote: > My *guess* at this time is that > > 1. The true cause of the error is a customer firewall or similar that is > blocking the connection. > > 2. The "anonymouslevel" text in the error message is totally spurious and > has nothing to do with reality. I have seen this before, where the "detail" > part of an FTP error message was devoid of a connection to reality. My > *suspicion* is that the component generating the error is failing to set > the > "reason code" (using the term in a general sense) correctly, leading the > message generation routine to insert spurious text. > > Charles > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Charles Mills > Sent: Monday, November 15, 2021 3:56 PM > To: [email protected] > Subject: FTP Switch between users not accepted as anonymouslevel = 3 > > Does anyone know what the heck I should be looking for on this? > > A customer running the z/OS FTP client is attempting to log into our FTP > server. The FTP client is ATTACHed dynamically with FTP -e -i -n > -f//DD:SYS00032 url.of.ftp.server > > The FTP client is passed an INPUT file that begins > > User userid password > > The output from the FTP client is > > EZA1736I FTP -e -i -n -f //DD:SYS00032 url.of.ftp.server > EZY2640I Using dd:SYS00032 for local site configuration parameters. > EZA1450I IBM FTP CS V2R3 > EZA1772I FTP: EXIT has been set. > EZA1554I Connecting to: url.of.ftp.server dotted.address port: 21. > EZA2589E Connection to server interrupted or timed out. USER command > failed. > Switch between users not accepted as anonymouslevel = 3 > EZA1735I Std Return Code = 10000, Error Code = 00008 > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN