I am trying to get a dump for IBM with the following commands: dump comm=(???? DUMP) r ##,jobname=(dt11mstr,dt11dbm1,dt11irlm,dt11dist,omvs),cont r ##,sdata=(rgn,csa,lsqa,sqa,psa,swa,lpa,trt,grsq,sum,allnuc),end
it keeps saying "IEE711I SYSTEM DUMP NOT TAKEN. ANOTHER DUMP WAS IN PROGRESS" I thought perhaps the second command (sdata) appeared to be getting truncated. it is that or does a dump need to be cleared? thanks Bill ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN