I'm with Mark on the unlikely impact of CPU upgrade on couple data sets. We went through a full push-pull upgrade in 2008 and another one-by-one push-pull in 2012. As long as the IODF is coded properly and recabling performed correctly, there should be no loss of access to any previously defined volume.
However, I'm also sympathetic to Lizette's complaint about the severe effect of losing all share control data sets. Our biggest user of RLS is HSM, which IIRC will not come up if RLS is broken. IPLing without HSM can be a nasty swim in the swamp. Providing an emergency definition in PARMLIB a la CFRMPOL parameter in COUPLExx might be a day saver. . . JO.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 626-302-7535 Office 323-715-0595 Mobile [email protected] From: Mark Zelden <[email protected]> To: [email protected], Date: 03/04/2013 07:55 AM Subject: Re: RLS SMSVSAM and PLEX wide IPL Sent by: IBM Mainframe Discussion List <[email protected]> On Sun, 3 Mar 2013 01:32:26 -0700, Lizette Koehler <[email protected]> wrote: >We upgraded the CPU this weekend, and SMSVSAM would not come up. > >We got the IGW611a and IGW609A messages > >After a bit of investigation, I did the V SMS,SHCDS(xxx),NEW putting back >the Prim/Sec/Spare files. > >There were no issues with the definition and the only changes were >un-cabling/re-cabling the DASD from the old CPU to the new CPU and IPLing >with new CF datasets. > >I am curious if when there is a PLEX wide IPL (All Lpars down at the same >time then IPL one at a time up) if there is some way to prevent the loss of >the SHCDS data set names? > >Any thoughts? > >My hunts through the manuals and internet is not providing much detail on >PLEX wide IPLs and SHCDS datasets > New CF (CFRM) couple data sets or new SYSPLEX (XCF) couple data sets? The names are stored in the sysplex couple ds. But you shouldn't replace either for a CPU upgrade. -- Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN