On Sun, 12 Jul 2020 05:17:08 -0400, David Spiegel <dspiegel...@hotmail.com> 
wrote:

Yes, of course.
The only valid indirect cataloging for PARMLIBs at LOADxx processing time are:

1) ******       (six asterisks)
2) *MCAT*      (Master Catalog's volume)
3)  &SYSRS1    

That's because their value is automatically established and "known" before 
processing any IEASYMxx member. 

>Hi Israel AMV"SH,
>Shavua Tov!
>A side point ... If SYS1.PARMLIB is CATALOGd via a Symbolic (e.g.
>&SYSR1) your IPL will fail, however, for a successful it can be CATALOGd
>via VOL(*).
>
>Regards,
>David

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to