We have both parallel sysplexes and monoplexes. SMS runs on every image. 

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
robin...@sce.com

-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Richards, Robert B.
Sent: Tuesday, May 19, 2020 8:58 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: (External):Re: Creating new SMS environment in a monoplex

CAUTION EXTERNAL EMAIL

Thanks, Radoslaw.

My point, and I think you have also confirmed it, is that an SMS environment 
has no specific dependence on a parallel sysplex, CFs, couple datasets, etc.

All that is left for me is to finish building the system and IPL it.

Bob


-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of R.S.
Sent: Tuesday, May 19, 2020 11:21 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Creating new SMS environment in a monoplex

W dniu 18.05.2020 o 20:36, Richards, Robert B. pisze:
> It has been a few decades since I have created a new SMS environment.
>
> Current environment is parallel sysplex replete with CFs and lots of lpars.
>
> I am trying to create a simple SMS environment that will be part of a 
> monoplex consisting on one lpar.
>
> I did the following:
>
>
>    1.  Defined the new SYSNAME into the base configuration in ISMF and 
> activated same. D SMS verified it was defined and not active
>    2.  A REPRO of the SCDS into a new SCDS dataset (Alter/newname to correct 
> usercat)
>    3.  Issued a SETSMS SAVEACDS(also using a SSA connector that I 
> subsequently ALTER NEWNAME the new ACDS into a new usercat that is connected 
> to a new mastercat)
>    4.  Defined an empty COMMDS that I also performed an alter/newname to get 
> the desired COMMDS dataset name.
>
> My boss says the ACDS is aware of the original sysplex environment and my 
> gyrations of trying to make the above work in a monoplex will not succeed.
>
> Who is right? Will it work or not?

Quick and dirty method:
1. Add new system name to existing SCDS and ACDS. Don't worry, it is nothing 
wrong to have non-present system names there.
2. Copy all *CDS to disk belonging to new system.
3. IPL the system.

Of course this is method for some migration. ACS routines, class definitions 
and library definitions will be moved. Is that what you want?
Otherwise there is another method, to start from scratch. ACS routines can be 
easily imported, class definitions - the only way I know is to re-define them 
manually.
BTW: some dummy SMS environment is delivered with ServerPac. I always start 
from that point. Then IPL with CPAC system name, then add my name to ACDS then 
reIPL with my system name. Then *CDS datasets can be imported (copied). Piece 
of cake.

--
Radoslaw Skorupka
Lodz, Poland


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to