On 2/16/2013 6:14 AM, John P Kalinich wrote:
The DVOL and PDS commands use the DCE (returned from UCBSCAN) to determine the 
3390 model number.  Until EAV, any volumes larger than a model 9 were 
identified as model 9.  The DCE model number for EAV DASD is A.

As Dale McCart points out, a "Mod6" volume (smaller than Mod9) is also shown as Mod9 by the DS,P command:

IEE459I 08.20.48 DEVSERV PATHS 206
 UNIT DTYPE  M CNT VOLSER  CHPID=PATH STATUS
      RTYPE  SSID CFW TC   DFW PIN DC-STATE CCA DDC       CYL CU-TYPE
08110,33909 ,O,000,T4RES1,12=+ 2E=+
      2107   8001  Y  YY.  YY.  N  SIMPLEX   10  10      6678 2107
************************ SYMBOL DEFINITIONS ************************
O = ONLINE                         + = PATH AVAILABLE

There is a SHARE requirement to document the DCE in MACLIB.

Cheryl Watson looked this up for me in the SHARE requirements system. The SHARE requirement number is SSMVSS12002. It contains the following. Don't shoot the messenger. :\

"Response Code: RJ-Rejected Date: 2012-10-26 by Response: IBM does not intend to provide a solution to this request for the following reason: Reject Reason : Technical Reject Explanation : The DCE is not intended to be an external API."

--
Edward E Jaffe
Phoenix Software International, Inc
831 Parkview Drive North
El Segundo, CA 90245
http://www.phoenixsoftware.com/

----------------------------------------------------------------------