I tried same thing again and problem got resolved. Now my SMF started working normally.
Thanks for helping me . Regards Saurabh On Fri, Sep 14, 2012 at 2:28 AM, Lizette Koehler <[email protected]>wrote: > You probably need to open an ETR/SR with IBM and have them look at this > issue. > > Lizette > > -----Original Message----- > >From: saurabh khandelwal <[email protected]> > >Sent: Sep 13, 2012 1:51 PM > >To: [email protected] > >Subject: Re: SMF Dataset CLOSE PENDING ISSUE > > > >Hello, > > I issued FORCE SMF,ARM command then then recreated MAN1 > >dataset and then issued T SMF=00 command. > > > >After issuing set SMf=00 command, man1 become active for a while but again > >it came to CLOSE PENDING status. > > > >Regards > >Saurabh > > > >On Fri, Sep 14, 2012 at 1:13 AM, saurabh khandelwal < > >[email protected]> wrote: > > > >> Yes, I also found same . > >> https://www-304.ibm.com/support/docview.wss?uid=isg1II02887 > >> > >> Looks like I need to issue > >> > >> FORCE SMF,ARM > >> > >> and then Set SMF=00 command to restart this > >> > >> > >> Regards. > >> Saurabh > >> > >> > >> On Fri, Sep 14, 2012 at 1:08 AM, Lizette Koehler < > [email protected]>wrote: > >> > >>> Text also from the old APAR > >>> > >>> If SMF is in a hang or hung situation: (added 11/14/00 LMM) > >>> - Issue the command, FORCE SMF,ARM > >>> This should trigger a dump for the SMF address space. > >>> - Use the IPCS SMFDATA command to retrieve SMF records > >>> contained in SMF's buffers. (Note, first allocate a > >>> dataset to contain these records. If necessary, refer > >>> to the SMF manual, Systems Management Facilities > >>> GC28-1783 on creating SMF datasets.) > >>> - To restart SMF, issue the SET command. For example, > >>> T SMF=BT > >>> - If there is a concern about the integrity of the SMF > >>> datasets, run the access method services VERIFY command > >>> against the dataset(s). > >>> - If one or more SMF datasets had the 'close pending' status > >>> as shown in the display command: D SMF > >>> use a different SMFPRMxx parmblib member in the SET command > >>> that does not include these datasets. (Create new SMF > >>> datasets if necessary.) Once the switch has been made, use > >>> the IFASMFDP program to dump the SMF datasets. > >>> > >>> > >>> Lizette > >>> > >>> > >>> -----Original Message----- > >>> >From: Lizette Koehler <[email protected]> > >>> >Sent: Sep 13, 2012 12:36 PM > >>> >To: [email protected] > >>> >Subject: Re: SMF Dataset CLOSE PENDING ISSUE > >>> > > >>> >DUMP COMM=(SMF DUMP) > >>> >the to the wtor > >>> > > >>> >XX,JOBNAME=SMF > >>> > > >>> > > >>> >Lizette > >>> > > >>> >-----Original Message----- > >>> >>From: saurabh khandelwal <[email protected]> > >>> >>Sent: Sep 13, 2012 12:29 PM > >>> >>To: [email protected] > >>> >>Subject: Re: SMF Dataset CLOSE PENDING ISSUE > >>> >> > >>> >>I just cheked in SMFPRM parmlib member, we are not collecting type 19 > >>> >>record. > >>> >> > >>> >>I tried issueing contention command > >>> >> > >>> >> > >>> >>D GRS,C > >>> >>ISG343I 12.27.22 GRS STATUS 959 > >>> >>NO ENQ RESOURCE CONTENTION EXISTS > >>> >>NO REQUESTS PENDING FOR ISGLOCK STRUCTURE > >>> >>NO LATCH CONTENTION EXISTS > >>> >> > >>> >>Can you please suggest, how to take console dump of SMF address > space. > >>> >> > >>> >>Regards > >>> >>Saurabh > >>> >> > >>> >>On Fri, Sep 14, 2012 at 12:53 AM, Lizette Koehler > >>> >><[email protected]>wrote: > >>> >> > >>> >>> From an old IBM Apar > >>> >>> At times, a SWITCH command fails to occur within a large amount > >>> >>> of time. This problem is usually seen when type19 records are > >>> >>> being collected. This is due to the fact that SMF issues the > >>> >>> LSPACE macro for every online device when information for > >>> >>> SMFtype19 records is being gathered. LSPACE then causes an ENQ > >>> >>> to be issued against each device. If an ENQ cannot be > >>> >>> satisfied, LSPACE processing will wait. Depending on what the > >>> >>> device is active for, the ENQ may take quite a while and the > >>> >>> SWITCH (I) command cannot complete. > >>> >>> > >>> >>> > >>> >>> Next, take a console dump of the SMF address space > >>> >>> > >>> >>> Then issue a D GRS,C command > >>> >>> > >>> >>> Let us know what you see. > >>> >>> > >>> >>> Lizette > >>> >>> > >>> >>> > >>> >>> > >>> >>> -----Original Message----- > >>> >>> >From: saurabh khandelwal <[email protected]> > >>> >>> >Sent: Sep 13, 2012 12:13 PM > >>> >>> >To: [email protected] > >>> >>> >Subject: Re: SMF Dataset CLOSE PENDING ISSUE > >>> >>> > > >>> >>> >I did the same, you suggested. But now D SMF command not showing > me > >>> any > >>> >>> >output. > >>> >>> > > >>> >>> >Not sure why. please suggest. > >>> >>> > > >>> >>> >Regards > >>> >>> >Saurabh > >>> >>> > > >>> >>> >On Fri, Sep 14, 2012 at 12:31 AM, McKown, John < > >>> >>> >[email protected]> wrote: > >>> >>> > > >>> >>> >> Is there some reason why you haven't created a MAN3; made a new > >>> >>> SMFPRMnn, > >>> >>> >> replacing MAN1 with a new MAN3; then doing the T SMF=nn command? > >>> Or have > >>> >>> >> you tried and it failed? If it works, it should get rid of the > >>> CLOSE > >>> >>> >> PENDING because the MAN1 entry will be gone and a new MAN3 entry > >>> >>> appear. If > >>> >>> >> that does happen, you can then dump MAN1. Once MAN1 has been > >>> dumped, you > >>> >>> >> can do a T SMF=00 (or whatever the IPL value is for SMFPRMnn) to > >>> remove > >>> >>> >> MAN3 and re-instate MAN1. Then dump MAN3 and delete it. > >>> >>> >> > >>> >>> >> -- > >>> >>> >> John McKown > >>> >>> >> Systems Engineer IV > >>> >>> >> IT > >>> >>> >> > >>> >>> >> Administrative Services Group > >>> >>> >> > >>> >>> >> HealthMarkets(r) > >>> >>> >> > >>> >>> >> 9151 Boulevard 26 * N. Richland Hills * TX 76010 > >>> >>> >> (817) 255-3225 phone * > >>> >>> >> [email protected] * www.HealthMarkets.com > >>> >>> >> > >>> >>> >> Confidentiality Notice: This e-mail message may contain > >>> confidential or > >>> >>> >> proprietary information. If you are not the intended recipient, > >>> please > >>> >>> >> contact the sender by reply e-mail and destroy all copies of the > >>> >>> original > >>> >>> >> message. HealthMarkets(r) is the brand name for products > >>> underwritten > >>> >>> and > >>> >>> >> issued by the insurance subsidiaries of HealthMarkets, Inc. -The > >>> >>> Chesapeake > >>> >>> >> Life Insurance Company(r), Mid-West National Life Insurance > >>> Company of > >>> >>> >> TennesseeSM and The MEGA Life and Health Insurance Company.SM > >>> >>> >> > >>> >>> >> > >>> >>> >> > -----Original Message----- > >>> >>> >> > From: IBM Mainframe Discussion List [mailto: > >>> [email protected]] > >>> >>> >> > On Behalf Of saurabh khandelwal > >>> >>> >> > Sent: Thursday, September 13, 2012 1:55 PM > >>> >>> >> > To: [email protected] > >>> >>> >> > Subject: Re: SMF Dataset CLOSE PENDING ISSUE > >>> >>> >> > > >>> >>> >> > I just dumped the MAN2 dataset. now D SMF shows MAN2 is > active > >>> but 67 > >>> >>> >> > % > >>> >>> >> > full. > >>> >>> >> > > >>> >>> >> > Now D SMF showing me > >>> >>> >> > > >>> >>> >> > IEE974I 11.45.18 SMF DATA SETS 652 > >>> >>> >> > NAME VOLSER SIZE(BLKS) %FULL STATUS > >>> >>> >> > P-SYS1.GBU1.MAN1 PLXU05 10800 99 CLOSE > >>> PENDING > >>> >>> >> > S-SYS1.GBU1.MAN2 PLXU05 10800 69 ACTIVE > >>> >>> >> > > >>> >>> >> > Can I use same > >>> >>> >> > > >>> >>> >> > > >>> >>> >> > //SMFDMPM JOB 'SAURABH', > >>> >>> >> > // NOTIFY=&SYSUID, > >>> >>> >> > // CLASS=A, > >>> >>> >> > // MSGCLASS=A > >>> >>> >> > //STEP1 EXEC PGM=IFASMFDP,REGION=4M > >>> >>> >> > //DUMPIN DD DSN=SYS1.GBU1.MAN2,DISP=SHR > >>> >>> >> > //DUMPOUT DD DISP=(NEW,CATLG),DSN=arit.SMF.GBU1.D091312, > >>> >>> >> > // > >>> UNIT=SYSALLDA,VOL=SER=STOR51,SPACE=(CYL,(30,10),RLSE), > >>> >>> >> > // DCB=(RECFM=VBS,LRECL=32760,BLKSIZE=4096) > >>> >>> >> > //SYSPRINT DD SYSOUT=* > >>> >>> >> > //SYSIN DD * > >>> >>> >> > INDD(DUMPIN,OPTIONS(ALL)) > >>> >>> >> > > >>> >>> >> > job for MAN1 dataset to take dump and clear it.. the way I > did > >>> for > >>> >>> >> > MAN2. > >>> >>> >> > > >>> >>> >> > please suggest. > >>> >>> >> > > >>> >>> >> > Regards > >>> >>> >> > Saurabh > >>> >>> >> > On Fri, Sep 14, 2012 at 12:11 AM, McKown, John < > >>> >>> >> > [email protected]> wrote: > >>> >>> >> > > >>> >>> >> > > I haven't researched this, but is there a way to "restart" > >>> SMF? I > >>> >>> >> > know > >>> >>> >> > > some system address spaces can be FORCE'd and then started > up > >>> again > >>> >>> >> > using > >>> >>> >> > > some procedure (which seems to be different depending on the > >>> system > >>> >>> >> > address > >>> >>> >> > > space). > >>> >>> >> > > > >>> >>> >> > > -- > >>> >>> >> > > John McKown > >>> >>> >> > > Systems Engineer IV > >>> >>> >> > > IT > >>> >>> >> > > > >>> >>> >> > > Administrative Services Group > >>> >>> >> > > > >>> >>> >> > > HealthMarkets(r) > >>> >>> >> > > > >>> >>> >> > > 9151 Boulevard 26 * N. Richland Hills * TX 76010 > >>> >>> >> > > (817) 255-3225 phone * > >>> >>> >> > > [email protected] * www.HealthMarkets.com > >>> >>> >> > > > >>> >>> >> > > Confidentiality Notice: This e-mail message may contain > >>> confidential > >>> >>> >> > or > >>> >>> >> > > proprietary information. If you are not the intended > recipient, > >>> >>> >> > please > >>> >>> >> > > contact the sender by reply e-mail and destroy all copies of > >>> the > >>> >>> >> > original > >>> >>> >> > > message. HealthMarkets(r) is the brand name for products > >>> >>> underwritten > >>> >>> >> > and > >>> >>> >> > > issued by the insurance subsidiaries of HealthMarkets, Inc. > >>> -The > >>> >>> >> > Chesapeake > >>> >>> >> > > Life Insurance Company(r), Mid-West National Life Insurance > >>> Company > >>> >>> >> > of > >>> >>> >> > > TennesseeSM and The MEGA Life and Health Insurance > Company.SM > >>> >>> >> > > > >>> >>> >> > > > >>> >>> >> > > > -----Original Message----- > >>> >>> >> > > > From: IBM Mainframe Discussion List [mailto:IBM- > >>> >>> >> > [email protected]] > >>> >>> >> > > > On Behalf Of Campbell Jay > >>> >>> >> > > > Sent: Thursday, September 13, 2012 1:38 PM > >>> >>> >> > > > To: [email protected] > >>> >>> >> > > > Subject: Re: SMF Dataset CLOSE PENDING ISSUE > >>> >>> >> > > > > >>> >>> >> > > > > >>> >>> >> > > > Take MAN1 out of SMFPRMxx when you put the new MAN3 in... > >>> Before T > >>> >>> >> > > > SMF=xx. > >>> >>> >> > > > Then do whatever you want with MAN1 while it's no longer > >>> allocated > >>> >>> >> > to > >>> >>> >> > > > SMF. > >>> >>> >> > > > Then put it back after it's fix ( deleted - redefined ) > >>> >>> >> > > > > >>> >>> >> > > > Jay Campbell > >>> >>> >> > > > IBM OS Support Section > >>> >>> >> > > > >>> >>> >> > > > >>> >>> > --------------------------------------------------------------------- > >>> >>> >> > - > >>> >>> >> > > For IBM-MAIN subscribe / signoff / archive access > instructions, > >>> >>> >> > > send email to [email protected] with the message: > INFO > >>> IBM- > >>> >>> >> > MAIN > >>> >>> >> > > > >>> >>> >> > > >>> >>> >> > > >>> >>> >> > > >>> >>> >> > -- > >>> >>> >> > Thanks & Regards > >>> >>> >> > Saurabh Khandelwal > >>> >>> >> > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > -- Thanks & Regards Saurabh Khandelwal ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN