On 12 Jun 2012 13:29:40 -0700, in bit.listserv.ibm-main you wrote:

>Clark stated,
>
>"If the statement //SYSOUT DD some parameters is missing and you have a
>DISPLAY something in your program and the LE runtime option CBLQDA is
>(ON), the program will dynamically allocate a temporary file with
>DISP=(NEW,DELETE) and write to it. This is true for all QSAM files.
>If the LE option is CBLQDA(OFF), you will get an abend on OPEN (or for
>DISPLAY, first write). CBLQDA(ON) is purportedly to conform to the
>COBOL standard although the standard assumed that the file would
>remain somewhere.
>
>Clark Morris"
>
>This is simply WRONG,  THE CBLQDA run-time option ONLY impacts the COBOL I/O
>verbs
>  Read
>  Write
>  REWRITE
>(actually - it really just applies to OPEN)
>
>It does NOT impact DISPLAY (or ACCEPT). See (for example)

Oops, this is a belated posting to say that my memory was obviously
bad.  My excuse is that I trying to remember from the 1995 - 1999 time
frame when I dealt with this.  

Clark Morris
> 
>http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/ceea31b0/1.2.11.1
>
>
>OP,
>  You MIGHT want to look at the ENQ/NOENQ suboption of MSGFILE.  It does
>talk about when an ATTACH is going on or other LE processes might be
>happening.
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN