This is not HALON related but it is along similar lines of others on here.

We had a T1 that worked perfectly AT&T (in the 1980's) said it was to spec and almost zero errors. One of my many part time responsibilities was for maintaining the 3725 software. Every so often the T1 (it was muxed) would go zonkers. I had AT&T and everyone looking at it and they could see it go crazy and were trying to pin down what was causing it. I had traces up the ying yang showing the issue but everything (software) was up to snuf and I had IBM level 2 scratching their heads as they could not see the issue either. It was getting semi serious as the NP was out pacing the floor and yelling at people. One of our people was talking to the people on the other end (NYC) and he made a comment about it seemed to happen when ever the freight elevator went by......

Turns out they didn't use shielded wiring in the elevator shaft (DAMM AT&T). They were out and replaced it and really never had an issue after that and we POURED data through it! Never a software issue (NCP or VTAM) it was solid as a rock just like good code should be.

Ed

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to