Another item worth mentioning, when z/OS changes the time based on an STP
change, the message IEA392I is issued. If you have an automation package, you
could rite automation that would catch this message and reset the time in CICS.
IEA392I description: One or more of the time offset values has
changed. These include leap seconds, local time, and daylight savings time
offsets.
Along these lines, I heard that some Omegamon tasks wanted a time reset command
also. The tasks appear to be mostly Omegamon II.
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of
John Norgauer
Sent: Monday, March 12, 2012 6:50 PM
To: [email protected]
Subject: Server time Protocol and CICS
This weekend we had our mainframe time automatically adjusted to Day Light
Time using S.T.P.. However, CICS did not get the time
changed automatically. Is CICS still unable to do this(have the time
changed automatically)?
John Norgauer
Senior Systems Programmer
Mainframe Technical Support Services
University of California Davis Medical Center
2315 Stockton Blvd
ASB 1300
Sacramento, Ca 95817
916-734-0536
SYSTEMS PROGRAMMING...... Guilty, until proven innocent !! " JN 2004
........