Good Afternoon Gentle Readers I am trying to trouble shoot the following problem : IEC331I 050-030(VVDSFULL, PROD06) According to the message error explanation it says that the VVDS is full. When I check via ISPF 3.4 is shows that it is a 1 ext. The VVDS was built at TRACKS(30 1). To fix the problem the doc says to move dsns off that volume. I tried that but the problem persists when the system is trying to allocate a dsn on the volume. Since the volume is SMS managed (phew), I put it at DISNEW. The doc says to backup the volume, and reinitialize it with a larger VVDS. Is there something else I can try before I try the doc's recommendation? Thanks in advance.
---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html