At 00:39 -0500 on 04/21/2011, Paul Gilmartin wrote about Re: Submit a series of jobs in order after the previous:

I could build multi-data-set tapes starting with a nonspecific
  VOLSER with the power of JCL.  I once did this in Rexx, scanning
  the TIOT (Thanks, Steve Bacher) for the volser of the first
  data set, and specifying that in the BPXDYN() for following
  data sets.  (I had to persuade my sysprog te allow me to
  DYNALLOC tapes.)  Then it dismounted, remounted, and repositioned
  the tape for each data set.  Yuck!  I want DYNALLOC RETAIN,VOL=REF.

DISP=PASS will leave the tape mounted and not rewound if I remember. I think that one of the SVC99 Parms supports RETAIN so you can go that route also.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to