The ZPSxxyyy is for text fields only.
So if I have a Rexx variable &var1
As a input/output field
FIELD(var1)
Sent from my iPhone
On Mar 22, 2011, at 7:34 AM, Robert Birdsall <[email protected]> wrote:
Just guessing from the manual...
have you tried
)PNTS
FIELD(field) VAR(VAR1) VAL(1)
Here's the manual info I'm going from:
For point-and-shoot input/output fields, the format is:
FIELD(field_name)
where:
field_name
The name of the field on the panel that this statement controls.
For point-and-shoot text fields, the format is:
FIELD(ZPSxxyyy)
where:
xx
00 for a point-and-shoot field defined in the )BODY section and 01
to 99 for
the number of the scrollable area in which the point-and-shoot text
field is
defined.
Each scrollable area is assigned a sequential number based on its
relative
position within the panel body. The scrollable area closest to the
upper-left
corner of the panel body is assigned number 01. Each additional
scrollable
area, scanning left to right, top to bottom, is assigned the next
sequential
number. A maximum of 99 scrollable areas in any given panel can
contain point-
and-shoot text fields.
yyy
001 to 999 for the relative number of the point-and-shoot text field
within the
panel body or within a particular scrollable area.
A point-and-shoot text field can wrap around multiple terminal lines
in panels
that are not displayed in a window. A point-and-shoot text field
that logically
wraps in a pop-up window requires the beginning of each wrapped line
to
contain a PS field attribute and an entry must exist in the )PNTS
section for
each wrapped line. This is also true for panels containing the WINDOW
()
keyword that are not displayed in a pop-up window. The additional )
PNTS
section entries should result in the same action as the first line
of the wrapped
text field.
On Fri, 18 Mar 2011 18:26:10 -0400, michealbutz
<[email protected]> wrote:
I can't seem to get Point and shoot right
The attribute field that is defined needs to have PAS(ON)
So for example
@ TYPE(INPUT) PAS(ON) COLOR(WHITE)
The )PNTS section defines the value to be placed in the point and
shoot
field )BODT
Point and shoot field ==> @field
)PNTS
FIELD(ZPS00001) VAR(&VAR1) VAL(1)
So if the user cursor selects the area where field is located a
value of 1
will be
placed variable var1
Excepts when I do a say ' var1 = ' var1 var1 value is
not 1
---
-------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN
INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,