Frank,
We will migrate from VSE to ZOS.
If I understand, We can first, change all program on VSE, removing the AS
prefix from SELECT, and then, use the SAM-ESDS (MSAM).
And, when migrate the source from VSE to Z/OS, no change is required correct ?
If is this idea, is very good, but I think that the developer people have no
time to change this, unfortunatelly.
Anyway, thanks very much from your help, and best regards.
Sergio
> Date: Thu, 17 Feb 2011 18:05:37 -0700
> From: [email protected]
> Subject: Re: Question about COBOL Program
> To: [email protected]
>
> What is your end goal? Is it to have the same source code work on both VSE
> and z/OS? Or are you just migrating to z/OS from VSE?
>
> If the former, I would recommend coding the select as non-VSAM (no AS-
> prefix). Then use a QSAM file on z/OS and a VSAM-managed SAM (MSAM; aka
> SAM-ESDS) on VSE. We just moved from VSE to z/OS last year. We used MSAM
> fairly extensively. No need for those awful EXTENT statements that are
> required by SD files.
>
> Of course, alternatively you could use VSAM ESDS instead of sequential on
> both VSE and z/OS. I know that z/OS shops prefer QSAM to ESDS in general (or
> so I've been told), but ESDS certainly is an option.
>
> Frank
> --
>
> Frank Swarbrick
> Applications Architect - Mainframe Applications Development
> FirstBank Data Corporation - Lakewood, CO USA
> P: 303-235-1403
>
>
> On 2/17/2011 at 12:44 PM, in message
> <[email protected]>, Sergio Lima
> <[email protected]> wrote:
> > Hello List,
> >
> > We had installed in our installation ZOS1.12 system , and also Z/VSE 4.2.
> > Under Z/VSE, is not very easy, work, with sequential files, if you don't
> > have a specific product for manage the VTOC space, that is our case.
> > Under Z/OS, it is not true, because, is not necessary specify the START of
> > a
> > LOCATION from a file in to disk.
> > So, We thing change all of our JCL, when the file is VSAM under Z//VSE : //
> > DLBL MYFILE,'MYFILE.VSAM',,VSAM , to sequential files under Z/OS,
> > //MYFILE DD DSN=MYFILE.SEQ,DISP=SHR, without change the source of a COBOL
> > program.
> >
> > The test that We made here, show that this is not possible, so, We want
> > know
> > the opinions of this list, if this is really true.
> >
> > In a single COBOL, we wrote :
> >
> > SELECT ARQSEQ ASSIGN TO SYS010-AS-ARQSEQ
> > FILE STATUS IS FS-ARQSEQ.
> >
> > Then running ok for VSAM, but not for a sequential file, had Return code =
> > 37.
> >
> > When running with this :
> >
> > SELECT ARQSEQ ASSIGN TO SYS010-UT-ARQSEQ
> >
> > Here, run ok for sequential file, but for VSAM had :
> >
> > IGZ0200W A file attribute mismatch was detected. File ARQSEQ in program
> > LESEQ was defined as a physical sequential
> > file and the file specified in the ASSIGN clause was a VSAM data
> > set.
> >
> > and the program end with Return code = 39.
> >
> > Thanks very much
> >
> > Sergio Lima Costa
> > Sao Paulo - Brazil
> >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to [email protected] with the message: GET IBM-MAIN INFO
> > Search the archives at http://bama.ua.edu/archives/ibm-main.html
>
> >>>
>
> The information contained in this electronic communication and any document
> attached hereto or transmitted herewith is confidential and intended for the
> exclusive use of the individual or entity named above. If the reader of this
> message is not the intended recipient or the employee or agent responsible
> for delivering it to the intended recipient, you are hereby notified that any
> examination, use, dissemination, distribution or copying of this
> communication or any part thereof is strictly prohibited. If you have
> received this communication in error, please immediately notify the sender by
> reply e-mail and destroy this communication. Thank you.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html