Hello,
We've recently implemented sysplex OPERLOG in a CF structure on Jan. 20th,
2011. This past weekend we started getting the following messages:
IXC585E STRUCTURE LCA_OPERLOG IN COUPLING FACILITY CFB1,
PHYSICAL STRUCTURE VERSION C73599B9 8DEB1D84,
IS AT OR ABOVE STRUCTURE FULL MONITORING THRESHOLD OF 80%.
ENTRIES: IN-USE: 9421 TOTAL: 10909, 86% FULL
ELEMENTS: IN-USE: 21908 TOTAL: 32546, 67% FULL
The log offloaded last Thursday while one system was being IPL'd. After this
is when these messages started.
Here is how LCA_OPERLOG is defined in the CF:
/* SYSPLEX OPERATOR SYSLOG (OPERLOG) */
STRUCTURE NAME(LCA_OPERLOG)
SIZE(25600)
INITSIZE(14336)
PREFLIST(CFB1)
And the logstream definitions:
DATA TYPE(LOGR)
DEFINE STRUCTURE NAME(LCA_OPERLOG)
LOGSNUM(1)
MAXBUFSIZE(4096)
DEFINE LOGSTREAM NAME(SYSPLEX.OPERLOG)
STRUCTNAME(LCA_OPERLOG)
HLQ(SYS0)
LS_DATACLAS(TSDLOGR)
LS_STORCLAS(STANDARD)
LS_SIZE(4096)
STG_DATACLAS(TSDLOGR)
STG_STORCLAS(STANDARD)
STG_SIZE(4096)
HIGHOFFLOAD(80)
LOWOFFLOAD(0)
AUTODELETE(YES)
RETPD(14)
We're confused. Did we set this up wrong? Any help and advice would be
greatly appreciated.
/Brad
Sorry about the company inserted disclaimer below.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html