On Fri, Oct 12, 2012 at 7:31 AM, Bas van der Vlies <b...@sara.nl> wrote: > > When i specify a time class like: > * Min20_25 > > Till which minute is this class valid. Is minute Min25 also valid? > > I have written a simple test and it show that Min25 is invalid
I seems to me that this should be expected. The "Min20_25" class should be valid for five minutes: from xx:20:00 to xx:25:00. If it were valid from the beginning of minute 20 through the end of minute 25, that would actually make it valid for six minutes! (Well, 5 minutes and 59 seconds.) If cf-execd is running cf-agent every 5 minutes, you might end up running the test two runs in a row, when that is clearly not intended. -Brad _______________________________________________ Help-cfengine mailing list Help-cfengine@cfengine.org https://cfengine.org/mailman/listinfo/help-cfengine