On Fri, Oct 12, 2012 at 7:31 AM, Bas van der Vlies <b...@sara.nl> wrote:
>
> When i specify a time class like:
>  * Min20_25
>
> Till which minute is this class valid. Is minute Min25 also valid?
>
> I have written a simple test and it show that Min25 is invalid

I seems to me that this should be expected. The "Min20_25" class
should be valid for five minutes: from xx:20:00 to xx:25:00. If it
were valid from the beginning of minute 20 through the end of minute
25, that would actually make it valid for six minutes! (Well, 5
minutes and 59 seconds.) If cf-execd is running cf-agent every 5
minutes, you might end up running the test two runs in a row, when
that is clearly not intended.

-Brad