May be worth looking at the functions in SVN/harbour/contrib/hbtpathy/telepath.prg
tp_ctrlcts( nPort, nNewCtrl )
tp_ctrlrts( nPort, nNewCtrl )
tp_iscts( nPort ) etc...
I think you will need to experiment as there is little documentation for this.
You could send text in small packets and wait for tp_iscts( nPort ) == .T.
between each.

Barry


AbeB wrote:
Hi Alex,
Thanks for quick reply.

In the printer it's enabled, but in software i have no clue how.

Any guidance?

Thanks,
abe



AbeB wrote:

I'm printing to serial printer with  hbtpathy.lib

f.e.
tp_send(1, 
replic("012345678901234567890012345678901234567890"+chr(13)+chr(10),1000 ) )
but it whould cause overflow in the printed output.

any help?

Not specific to telepathy, but you must enable flow control on the printer and in your software. Most common are DTR/DTS (hardware) or XOn/XOff (software).

HTH
Alex
_______________________________________________