the .toc section in powerpc64le modules are sometimes not aligned on a four byte boundary. This fails the module linker especially when processing R_PPC64_TOC16_LO_DS, since the addresses are expected to be aligned on 4byte boundary.
Signed-off-by: Ram Pai <linux...@us.ibm.com> --- grub-core/kern/dl.c | 5 +++++ 1 file changed, 5 insertions(+) diff --git a/grub-core/kern/dl.c b/grub-core/kern/dl.c index ce2ff38..ee69c3c 100644 --- a/grub-core/kern/dl.c +++ b/grub-core/kern/dl.c @@ -304,7 +304,12 @@ grub_dl_load_segments (grub_dl_t mod, const Elf_Ehdr *e) { void *addr; +#ifdef __powerpc64le__ + ptr = (char *) ALIGN_UP ((grub_addr_t) ptr, + (s->sh_addralign < 4 ? 4 : s->sh_addralign)); +#else ptr = (char *) ALIGN_UP ((grub_addr_t) ptr, s->sh_addralign); +#endif addr = ptr; ptr += s->sh_size; -- 1.8.5.3 _______________________________________________ Grub-devel mailing list Grub-devel@gnu.org https://lists.gnu.org/mailman/listinfo/grub-devel