2017. április 27., csütörtök 18:18:19 UTC+2 időpontban Didier Spezia a 
következőt írta:
>
>
> I'm not sure it can help with the problem, but starting with Oracle 11, 
> OCI installs some custom signal handlers (even catching segmentation 
> faults).
> They can be deactivated by setting options in the sqlnet.ora file.
> Here, we run all our OCI clients with:
>
> DIAG_SIGHANDLER_ENABLED=FALSE
> DIAG_ADR_ENABLED=FALSE
> DIAG_DDE_ENABLED=FALSE
>
> Regards,
> Didier.
>
>>
>>
Thanks a lot, Didier! 

-- 