On 2013-06-01 02:24, Marcelo Vanean wrote:

> Hello to everyone. In version 4.5.5, calculating the viscosity with the
> command g_energy -vis, the generated files (eviscoi.xvg, eviscoi.xvg and
> visco.xvg) are inconsistent. The file evisco.xvg, for example, gives a
> value of zero for viscosity using the Einstein relation. Another question
> in 4.0.7, the file eviscoi.xvg is approximately a straight line, whereas in
> version 4.5.5 not. Why the Gromacs 4.0.7 gives the result in this way?
> Evidently, there is an inconsistency in these different results. Help me,
> please.
>
>
I used the same energy file (ener.edr) and I get this results:
http://help-gromacs.blogspot.com.br/. The files visco.xvg are equals.
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to