On Thu, 2012-05-03 at 18:43 +0200, Patrick Fuchs wrote: 
> Hi Florian,
> 
> >> I remark that Langevin method is used also for explicit water system!
> >
> > But there a big question arises to me. The thermostatting by Langevin is
> > achieved due to random kicks. If I simulate all atoms explicitly, there
> > is only vacuum between the atoms. Where do the random kicks come from
> > and how do I set gamma, which is actually related to the viscosity of
> > the medium I am simulating in? If my medium is vacuum, then gamma should
> > be zero, shouldn't it, and gamma=0 means no coupling, and hence,
> > Newton's equation of motion are recovered.
> >
> > I am not an expert with the Langevin thermostat, so this are serious
> > questions that arise to me now. Furthermore I also thought, that
> > Langevin dynamics were exactly established for a description of a system
> > within a medium.
> The use of Langevin dynamics (SD) to mimic solvant implicitely or as a 
> thermostat in explicit systems depends on the friction coefficient you 
> choose. It has to be chosen with care, see for example 
> http://dx.doi.org/10.1007/b99427 or the GROMACS manual. In explicit 
> simulations, SD with the appropriate choice of friction coefficient can 
> be seen as a local thermostat. The advantage is that it samples the 
> canonical ensemble (in the old versions of GROMACS it was the only way 
> to get the canonical ensemble before the implementation of Nose-Hoover 
> or velocity rescaling).

Hi, thank you very much for pointing to this very interesting article.
However, though the method seems to work, gamma has a very big
influence. I also think, that this kind of coupling is not a good
picture for an explicit simulation, because there is nothing in space
where friction can arise from, so a reference how to obtain gamma is not
given. 

But thanks everybody of you for the nice discussion.

/Flo

> Ciao,
> 
> Patrick
> -- 
> _______________________________________________________________________
> Patrick FUCHS
> Dynamique des Structures et Interactions des Macromolécules Biologiques
> INTS, INSERM UMR-S665, Université Paris Diderot,
> 6 rue Alexandre Cabanel, 75015 Paris
> Tel : +33 (0)1-44-49-30-57 - Fax : +33 (0)1-43-06-50-19
> E-mail address: patrick.fu...@univ-paris-diderot.fr
> Web Site: http://www.dsimb.inserm.fr/~fuchs

-- 
Florian Dommert
Dipl. - Phys.

Institute for Computational Physics
University Stuttgart

Pfaffenwaldring 27
70569 Stuttgart

EMail: domm...@icp.uni-stuttgart.de
Homepage: http://www.icp.uni-stuttgart.de/~icp/Florian_Dommert

Tel.: +49 - (0)711 - 68563613
Fax.: +49 - (0)711 - 68563658

Attachment: signature.asc
Description: This is a digitally signed message part

-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to