Justin,
10 апреля 2012 г. 16:21 пользователь Justin A. Lemkul <[email protected]>написал: > > I have never used the bd integrator so I cannot offer any help here. I > don't see any magical reason why you should expect it to enhance sampling > though. I've found in the literature that this integrator could rise the integration-time-step from common 1-2fs used with the MD-integrator. By the way I've tried to test my system equilibrated in the hight temperature in different conditions. As the consequence when I've removed all posres ( on the last stage of equilibration it's value was 200 for backbone atoms only) from my protein the alpha helixes have been destabilised already after 3ns of such unconstrained simulation ( ref_t= 700k). So I suppose that the presence of the some constrained factor is needed to prevent destabilisation but allow conformation sampling. I see three alternative ways of my production MD run with enhanced sampling. 1- First of all as the most trivial way I'm thinking of using soft posres applied on backbone atoms only with the constained value ( 50-100 kj*nm2) corresponded to the energy of the thermal motion. 2- Also I've thought about application of the harmonic distance_restraince (instead of posres) on the all backbone atoms exept of flexible loops where this disres must be in the longer range ( e.g up to 15-20A) but I could not realise about usefullness of such aproach because I cant define value for such disres for the atoms in helixes. It's known that conformation transitions wich I want to ssample accompanied by the large scale motions in the helical segments ( up to 10-15 A). At the same time such big fluctuations on the other atoms may destabiise regions wich are more rigid. Should I define several sets of restrains for my protein to allow one regions move with bigger amplitudes in comparison with rigid fragments ? 3- Finally alternative aproach is the ussage of common temperature ( ref_t=310k) in the production run but using starting velocities obtained from the nvt equilibrration obtained with the hight ( 700k) temperature. Can I enhance sampling using that starting conditions ? What from this three strategies is the most suitable? IS there any alternative ways for such high-temperature simulation ? Thanks for help again, James
-- gmx-users mailing list [email protected] http://lists.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/Search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [email protected]. Can't post? Read http://www.gromacs.org/Support/Mailing_Lists