Dear Justin A. Lemkul: Thanks for your rapid reply.
Just as you said, the result of my simulation with different xy p_ref values didn't vary, they are almost the same. I think I need consider some other ways to do what I was mean to do. I have read a paper that study the different lateral pressure profiles of lipid membrane with respect to sterol type, I think I may chose this as a way to produce different pressure profiles. Ollila, O. H. S., T. Rog, et al. (2007). "Role of sterol type on lateral pressure profiles of lipid membranes affecting membrane protein functionality: Comparison between cholesterol, desmosterol, 7-dehydrocholesterol and ketosterol." Journal of Structural Biology 159(2): 311-323. And, what's more, Do you think steered MD is a choice? KONG Xian
-- gmx-users mailing list gmx-users@gromacs.org http://lists.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/Search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org. Can't post? Read http://www.gromacs.org/Support/Mailing_Lists