shivangi nangia wrote:
Hello,

I am having problems in carrying out a NPT equilibration of my system at 500 K.

System: A 5 nm cube with peptide, Li+ ions and 2,5-dihydroxybenzoic acid anion.

NVT equilibration gives expected results.

When I load the npt.gro file in VMD, its seems as if the molecules have fragmented/vaporized.

nvt.mdp:

title    = hist NPT equilibration
define      = -DPOSRES  ; position restrain the protein
; Run parameters
integrator  = md     ; leap-frog integrator
nsteps      = 50000     ; 2 * 50000 = 100 ps
dt    = 0.002     ; 2 fs
; Output control
nstxout     = 100    ; save coordinates every 0.2 ps
nstvout     = 100    ; save velocities every 0.2 ps
nstenergy   = 100    ; save energies every 0.2 ps
nstlog      = 100    ; update log file every 0.2 ps
; Bond parameters
continuation   = yes    ; Restarting after NVT
constraint_algorithm = lincs  ; holonomic constraints
constraints = all-bonds ; all bonds (even heavy atom-H bonds) constrained
lincs_iter  = 1      ; accuracy of LINCS
lincs_order = 4      ; also related to accuracy
; Neighborsearching
ns_type     = grid      ; search neighboring grid cells
nstlist     = 5      ; 10 fs
rlist    = 1.0    ; short-range neighborlist cutoff (in nm)
rcoulomb = 1.0    ; short-range electrostatic cutoff (in nm)
rvdw     = 1.0    ; short-range van der Waals cutoff (in nm)
; Electrostatics
coulombtype = PME    ; Particle Mesh Ewald for long-range electrostatics
pme_order   = 4      ; cubic interpolation
fourierspacing = 0.16      ; grid spacing for FFT
; Temperature coupling is on
tcoupl      = V-rescale ; modified Berendsen thermostat
tc-grps     = Protein Non-Protein   ; two coupling groups - more accurate
tau_t    = 0.1 0.1   ; time constant, in ps
ref_t    = 500    500   ; reference temperature, one for each group, in K
; Pressure coupling is on
pcoupl      = Parrinello-Rahman  ; Pressure coupling on in NPT
pcoupltype  = isotropic ; uniform scaling of box vectors
tau_p    = 2.0    ; time constant, in ps
ref_p    = 1.0    ; reference pressure, in bar
compressibility = 4.5e-5   ; isothermal compressibility of water, bar^-1
; Periodic boundary conditions
pbc      = xyz    ; 3-D PBC
; Dispersion correction
DispCorr = EnerPres  ; account for cut-off vdW scheme
; Velocity generation
gen_vel     = no     ; Velocity generation is off


If I use the same exact system and run NVT and NPT equilibration at 300 K, everything seems to be working.

What could be going wrong at 500 K?


High temperature breaks down the water model and it, as you say, vaporizes. NVT is often more suitable for high-temperature MD for this very reason.

-Justin

Thanks,
Shivangi


--
========================================

Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
MILES-IGERT Trainee
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin

========================================
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to