quantrum75 wrote:
Hi GMX-users,
I am beginning to use the steered molecular dynamics method to perform a potential of mean field calculation. In your experience, does it matter what kind of a thermostat and pressure coupling is used? Does Nose-Hoover and Parinello-Rahman perform better than Berendsen for this purpose? Does it even matter?


That depends on how rigorously correct you want your ensemble to be. Berendsen coupling does not generate temperatures/pressures that correspond to any known statistical mechanical ensemble. This issue has been discussed dozens of times across this list. Check the archives (and the literature) for details.

Also with regards to the constraints on the bonds using the "all-bonds" option, Does it matter? I worry that applying constraints on the molecule being pulled will prevent it from sampling the configurational space effectively and thus giving false results on the PMF and binding energies. Maybe I am completely off the mark here.

See the manual, section 6.3, where this very topic is discussed.

-Justin

Thanks in advance.
Regards
Rama



--
========================================

Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
MILES-IGERT Trainee
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin

========================================
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to