Gavin Melaugh wrote:
There are 168 atom types in my system, 2 molecules comprising of 84
atoms each. The average temperature is 600 K but there are large
fluctuations ca ~100 K, which I assume is expected with such a smal
system. Ill check the energies
I would think it possible, even likely, that the thermostat is driving the
behavior of your system, since it contains so few atoms. Do check to see if
temperature spikes correlate with movement of your pull_group to one side of the
sampling window. If it is the problem, try a different thermostat (or at least
longer tau_t with N-H), and/or a substantially stronger pull_k1 if you're sure
you need/want N-H as your thermostat.
I certainly agree with Chris' proposed test with two water molecules. If you
see the same thing, I'm even more confident that I'm right :)
-Justin
Gavin
Justin A. Lemkul wrote:
Gavin Melaugh wrote:
O.K Thanks
My apologies for not stating earlier that I had the box dimensions set
to zero but I thought that when you set pbc = no and ns_type = simple
that "ignore the box" (from manual) was implemented.
Indeed.
How many atoms are in your system? How well-conserved is the
temperature? I imagine that if you only have a few atoms (relative to
a normal condensed-phase system), the species involved would be fairly
strongly impacted by the (potentially) wide oscillations of the
Nose-Hoover thermostat. Maybe the thermostat is kicking your system
around? Check the relevant energies and see if they sync up with the
configurations moving back and forth.
-Justin
Gavin
Justin A. Lemkul wrote:
Gavin Melaugh wrote:
Justin
In regard to my query regarding the cut-offs at zero with no pbc. I
assume its is fine to have box dimensions (0 0 0) to comply with the
definition of a vacuum simulation. I am just worried that there may be
some default cut-off that I am not aware of.
You have a box of zero size? That doesn't make any sense to me, and I
doubt that such a setup plays nice with the MD code. Frankly, I don't
see how it worked at all.
What if you place your system in a big box, no PBC, cutoffs = 0,
etc? Does that give you a sensible result?
Cheers
P.S I have plotted the pullx.xvg files for the distances between the
COMs of the molecules in the problematic windows. As was the case with
plotting with g_dist there is significant population of the at the
extremities of the window compared to that around the average r0.
Then technically, the average is probably fine, so the pull code is
satisfied. The sampling is clearly messed up for some reason. Keep
digging :)
-Justin
Justin A. Lemkul wrote:
chris.ne...@utoronto.ca wrote:
I have seen this before, and there are a few possible reasons, but
I'm still waiting to see that histogram with two peaks
(http://lists.gromacs.org/pipermail/gmx-users/2010-August/053311.html).
It's really hard to help you when we have to guess what the problem
looks like... or perhaps you posted it and I missed it?
The histogram was posted several days ago:
http://lists.gromacs.org/pipermail/gmx-users/2010-August/053317.html
The attachment link is:
http://lists.gromacs.org/pipermail/gmx-users/attachments/20100820/fc07fb81/histo.ps.bin
-Justin
-- original message --
O.K thanks anyway
Justin A. Lemkul
wrote:http://lists.gromacs.org/pipermail/gmx-users/2010-August/053311.html
Gavin Melaugh wrote:
Thanks Justin
Have you any idea why when generating umbrella histograms for the
pmf I
would get two peaks in the histograms above a distance of 2 nm,
but
below 2 nm I get well behaved histograms that lead to a very
good profile in the pmf. To the best of my knowledge the
configurations
are all very well equilibrated at their respective COM distances.
Umbrella sampling is performed on all windows using a force
constant of
1000 kj/mol at 600 K.
Sorry, no clue.
--
========================================
Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
MILES-IGERT Trainee
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin
========================================
--
gmx-users mailing list gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php