There *should* be no preference, but I seem to remember that one of the 
artifacts of using Ewald-style electrostatic treatment (such as PME) is that 
there may be dipole-coupling between periodic images, especially if one 
symmetry has already been broken. 
That doesn't mean you shouldn't use PME, though: you're a long way off from the 
thermodynamic limit, so you can't rely on fluctuations being slow. The 
situation you're describing will always happen, and with a small number of 
particles (i.e. less than you can see with the naked eye) it will happen sooner 
rather than later.

Sander


On Mar 30, 2010, at 18:00 , sapna sarupria wrote:

> Hi Sander
> Thanks for your response. Is there then a preference for z-dimension to 
> expand (other than the way the system is setup in terms of semi-isotropic 
> coupling). Would one see an expansion in any one direction if I had the same 
> system setup with independent pressure coupling for each dimension 
> (anisotropic)? 
> 
> Thanks,
> Sapna
> 
> On Tue, Mar 30, 2010 at 11:53 AM, Sander Pronk <[email protected]> wrote:
> It sounds like the normal thing that would happen if you have a system that 
> has no shear elastic constant, like a fluid. 
> In that case, there are no restoring forces against growth of system size in 
> one coordinate with a concomitant decrease in the other coordinates, so 
> eventually this should happen (unless I misunderstand the nature of your 
> system).
> 
> Sander
> 
> 
> On Mar 30, 2010, at 17:47 , sapna sarupria wrote:
> 
>> Hello all,
>> 
>> I have a simulation running for a hydrate (with CO2) and water in contact 
>> with each other. I run the simulation at 280K at which the hydrate melts and 
>> finally the system is just liquid water with CO2 in it. However, as the 
>> simulation proceeds the box begins to expand in the z-direction and 
>> decreases in the x-y direction considerably. Initially the box has 
>> 4.8x4.8x9.6 nm^3 dimensions. After the hydrate melts (the volume fluctuates 
>> more) and is fine for another 10 ns but after that the dimensions in the x-y 
>> direction decrease to 2.5 nm and z-dimension increases to 35 nm. At this 
>> point the simulation crashes since my cut-off distance are 1.2 nm. 
>> 
>> I am using semi-isotropic pressure coupling but the pressure in the x-y 
>> direction and z-direction are the same (=30.5 bar) and so is the 
>> compressibility (=4.5e-5). I am using Parrinello-Rahman pressure coupling 
>> and Nose-Hoover thermostat. The CO2 and water molecules are rigid and shake 
>> is used to maintain their geometry. The simulation time step is 2 fs. Can 
>> someone tell me why such a thing happens? I have pasted my mdp file for 
>> completeness. I am using Gromacs  4.0.5 and I run the simulations in 
>> parallel using 4 processors. Values related to domain decomposition etc are 
>> unchanged and the default values are used.
>> 
>> Any insights will be helpful. Thanks for the help.
>> 
>> MDP File:
>> title               =  CO2 hydrate + water      ; a string
>> cpp                 =  /lib/cpp                 ; c-preprocessor
>> dt                  =  0.002                    ; time step
>> nsteps           =  25000000            ; number of steps
>> nstcomm       =  10                           ; reset c.o.m. motion
>> nstxout          =  20000                    ; write coords
>> nstvout          =  20000                    ; write velocities
>> nstlog            =  25000                    ; print to logfile
>> nstenergy      =  500                   ; print energies
>> xtc_grps        =  OW_HW1_HW2_CO2
>> nstxtcout       =  500
>> nstlist             =  10                       ; update pairlist
>> ns_type          =  grid                     ; pairlist method
>> coulombtype   =  PME
>> rvdw                =  1.2                      ; cut-off for vdw
>> rcoulomb         =  1.2                      ; cut-off for coulomb
>> rlist                  =  1.2                      ; cut-off for coulomb
>> DispCorr          =  EnerPres
>> Tcoupl              =  Nose-Hoover
>> ref_t                 =  300
>> tc-grps             =  System
>> tau_t                 =  0.5
>> Pcoupl              =  Parrinello-Rahman
>> Pcoupltype       =  semiisotropic            ; pressure geometry
>> tau_p               =  1.0   1.0                ; p-coupling time
>> compressibility     =  4.5e-5  4.5e-5           ; compressibility
>> ref_p               =  30.5  30.5               ; ref pressure
>> gen_vel             =  yes                      ; generate initial vel
>> gen_temp            =  200                      ; initial temperature
>> gen_seed            =  372340                   ; random seed
>> constraint_algorithm = shake
>> constraints         =  all-bonds
>> 
>> 
>> 
>> Thanks a lot
>> Sapna
>> 
>> 
> 
> -- 
> gmx-users mailing list    [email protected]
> http://lists.gromacs.org/mailman/listinfo/gmx-users
> Please search the archive at http://www.gromacs.org/search before posting!
> Please don't post (un)subscribe requests to the list. Use the 
> www interface or send it to [email protected].
> Can't post? Read http://www.gromacs.org/mailing_lists/users.php

-- 
gmx-users mailing list    [email protected]
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to