Hi,

Is it desirable that genion only considers a single SOL block? Why not use them all if there are many?

Regards,

Erik

Berk Hess skrev:
Hi,

genion in future Gromacs versions will only use the last SOL block
and give a proper error message when there is not enough water.

Berk

------------------------------------------------------------------------
From: iitd...@gmail.com
Date: Thu, 11 Feb 2010 16:45:06 +0530
Subject: Re: [gmx-users] Software inconsistency error: Not enough water
To: gmx-users@gromacs.org


Thanks berk.
By the way, if I dont give -p topol.top as input to genion, then genion executes. In this case, I manually edit the topology file and add the ion information.
 [ molecules ]
; Compound        #mols
Protein_A           1
Protein_B           1
Protein_C           1
Protein_D           1
Protein_E           1
SOL                32
SOL                46
SOL                 3
SOL                13
SOL             19791
Na                 48

This is my part of topology after adding ions (Na). In the previous case of genion was only considering first SOL information, which has only 32 molecules.

Chandan

--
Chandan kumar Choudhury
NCL, Pune
INDIA


On Thu, Feb 11, 2010 at 3:38 PM, Berk Hess <g...@hotmail.com <mailto:g...@hotmail.com>> wrote:

    Hi,

    This error message in incorrect, it is probably not a software
    inconsistency.
    Looking at the code, it seems the problem is that the topology file
    you provided does not have enough SOL molecules in the [molecules
    ] section.
    I'll fix this error message for the next release.

    Berk

    ------------------------------------------------------------------------
    From: iitd...@gmail.com <mailto:iitd...@gmail.com>
    Date: Thu, 11 Feb 2010 12:48:53 +0530
    To: gmx-users@gromacs.org <mailto:gmx-users@gromacs.org>
    Subject: [gmx-users] Software inconsistency error: Not enough water


    Hello gmxusers !!
    I am simulating a protein and it  is bound to ATP.
    Simulation of protein alone (without) works fine. Solely ATP
    simulation too works. But the problem arises on adding ions to the
    protein + ATP (1QHH.pdb) file.
    Error:


    $ genion -s em.tpr -o ion.pdb -p topol.top -np 48
WARNING: turning of free energy, will use lambda=0 Reading file em.tpr, VERSION 4.0.7 (single precision) Using a coulomb cut-off of 0.9 nm Will try to add 48 Na ions and 0 Cl ions. Select a continuous group of solvent molecules Opening library file
    /usr/local/gromacs/share/gromacs/top/aminoacids.dat
    Group     0 (      System) has 70056
elements Group 1 ( Protein) has 10214 elements Group 2 ( Protein-H) has 5107 elements Group 3 ( C-alpha) has 623 elements Group 4 ( Backbone) has 1869 elements Group 5 ( MainChain) has 2488 elements Group 6 (MainChain+Cb) has 3083 elements Group 7 ( MainChain+H) has 3099 elements Group 8 ( SideChain) has 7115 elements Group 9 ( SideChain-H) has 2619 elements
    Group    10 ( Prot-Masses) has 10214 elements
    Group    11 ( Non-Protein) has 59842 elements
    Group    12 (         ATP) has    43 elements
    Group    13 (         SOL) has 59799 elements
    Group    14 (       Other) has 59842 elements
    Select a group: 13
    Selected 13: 'SOL'
    Number of (3-atomic) solvent molecules: 19933

    Processing topology

    Back Off! I just backed up temp.top to ./#temp.top.1#

    -------------------------------------------------------
    Program genion, VERSION 4.0.7
    Source code file: gmx_genion.c, line: 269

    Software inconsistency error:
    Not enough water
    -------------------------------------------------------

    Though my system has sufficient amount of water (19933) molecules.
    Can not understand the error. Any information would be useful.


    Chadan
    --
    Chandan kumar Choudhury
    NCL, Pune
    INDIA

    ------------------------------------------------------------------------
    Express yourself instantly with MSN Messenger! MSN Messenger
    <http://clk.atdmt.com/AVE/go/onm00200471ave/direct/01/>

    --
    gmx-users mailing list    gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
    http://lists.gromacs.org/mailman/listinfo/gmx-users
    Please search the archive at http://www.gromacs.org/search before
    posting!
    Please don't post (un)subscribe requests to the list. Use the
    www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
    Can't post? Read http://www.gromacs.org/mailing_lists/users.php



------------------------------------------------------------------------
Express yourself instantly with MSN Messenger! MSN Messenger <http://clk.atdmt.com/AVE/go/onm00200471ave/direct/01/>


--
-----------------------------------------------
Erik Marklund, PhD student
Laboratory of Molecular Biophysics,
Dept. of Cell and Molecular Biology, Uppsala University.
Husargatan 3, Box 596,    75124 Uppsala, Sweden
phone:    +46 18 471 4537        fax: +46 18 511 755
er...@xray.bmc.uu.se    http://xray.bmc.uu.se/molbiophys

--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to