Dear Sir, I want to pull a molecule called PRO from the lipid membrane DPP. To do this I have written the .mdp file as following from the help of gromacs mannual 4.0 . But when I try to make .tpr file from the .gro file, it says that "segmentation fault". Can you please write the correct .mdp file for the pulling? It will be really a great help to me. Thanking you, Anirban
; ; File 'mdout.mdp' was generated ; By user: psn (17109) ; On host: p690k ; At date: Fri Jul 23 12:43:31 2004 ; ; VARIOUS PREPROCESSING OPTIONS = title = lipid bilayer in water cpp = /lib/cpp include = define = ; RUN CONTROL PARAMETERS = integrator = md ; start time and timestep in ps = tinit = 500 dt = 0.002 nsteps = 1750000 ; mode for center of mass motion removal = comm-mode = Linear ; number of steps for center of mass motion removal = nstcomm = 1 ; group(s) for center of mass motion removal = comm-grps = ; LANGEVIN DYNAMICS OPTIONS = ; Temperature, friction coefficient (amu/ps) and random seed = ;bd-temp = 300 ;I have commute the above line as it has no exitance bd-fric = 0 ld-seed = 1993 ; ENERGY MINIMIZATION OPTIONS = ; Force tolerance and initial step-size = emtol = 100 emstep = 0.01 ; Max number of iterations in relax_shells = niter = 20 ; Step size (1/ps^2) for minimization of flexible constraints = fcstep = 0 ; Frequency of steepest descents steps when doing CG = nstcgsteep = 1000 ; OUTPUT CONTROL OPTIONS = ; Output frequency for coords (x), velocities (v) and forces (f) = nstxout = 5000 nstvout = 5000 nstfout = 0 ; Output frequency for energies to log file and energy file = nstlog = 250 nstenergy = 250 ; Output frequency and precision for xtc file = nstxtcout = 0 xtc-precision = 1000 ; This selects the subset of atoms for the xtc file. You can = ; select multiple groups. By default all atoms will be written. = xtc-grps = ; Selection of energy groups = energygrps = ; NEIGHBORSEARCHING PARAMETERS = ; nblist update frequency = nstlist = 10 ; ns algorithm (simple or grid) = ns_type = grid ; Periodic boundary conditions: xyz or no = pbc = xyz ; nblist cut-off = rlist = 1.0 domain-decomposition = no ; OPTIONS FOR ELECTROSTATICS AND VDW = ; Method for doing electrostatics = coulombtype = PME ;Reaction-Field rcoulomb-switch = 0 rcoulomb = 1.0 ;2.0 ; Dielectric constant (DC) for cut-off or DC of reaction field = epsilon_r = 80.0 epsilon_rf = 1 ;I have done some thing new according to mannual and warnings and error ; Method for doing Van der Waals = vdwtype = Cut-off ; cut-off lengths = rvdw-switch = 0 rvdw = 1.0 ; Apply long range dispersion corrections for Energy and Pressure = DispCorr = No ; Spacing for the PME/PPPM FFT grid = fourierspacing = 0.12 ; FFT grid size, when a value is 0 fourierspacing will be used = fourier_nx = 0 fourier_ny = 0 fourier_nz = 0 ; EWALD/PME/PPPM parameters = pme_order = 4 ewald_rtol = 1e-05 ewald_geometry = 3d epsilon_surface = 0 optimize_fft = yes ; OPTIONS FOR WEAK COUPLING ALGORITHMS = ; Temperature coupling = Tcoupl = berendsen ; Groups to couple separately = tc-grps = DPP SOL PRO ; Time constant (ps) and reference temperature (K) = tau_t = 0.1 0.1 0.1 ref_t = 310 310 310 ; Pressure coupling = Pcoupl = berendsen Pcoupltype = semiisotropic ; Time constant (ps), compressibility (1/bar) and reference P (bar) = tau_p = 1.0 1.0 compressibility = 4.5e-5 4.5e-5 ref_p = 1.0 1.0 ; SIMULATED ANNEALING CONTROL = annealing = no ; Time at which temperature should be zero (ps) = ;zero-temp_time = 0 ;I have commute the above line as it has no exitance ; GENERATE VELOCITIES FOR STARTUP RUN = gen_vel = yes gen_temp = 310.0 gen_seed = 173529 ; OPTIONS FOR BONDS = constraints = all-bonds ; Type of constraint algorithm = constraint_algorithm = lincs ; Do not constrain the start configuration = continuation = yes ;unconstrained-start = no ; Use successive overrelaxation to reduce the number of shake iterations = Shake-SOR = no ; Relative tolerance of shake = shake-tol = 0.0001 ; Highest order in the expansion of the constraint coupling matrix = lincs_order = 4 ; Lincs will write a warning to the stderr if in one step a bond = ; rotates over more degrees than = lincs-warnangle = 30 ; Convert harmonic bonds to morse potentials = morse = no ;COM pulling pull = umbrella pull_geometry = cylinder pull_dim = N N Y pull_r1 = 1 pull_r0 = 1 ;pull_constr_tot = 1e-6 pull_start = yes pull_nstxout = 10 pull_nstfout = 1 pull_ngroups = 1 ;name of reference group pull_group0 = DPP ;pull_weights = 0 ;name of pull group pull_group1 = PIP ;pull_weights = 0 pull_vec1 = 0.0 0.0 -1 ;ref. distance at t=0 pull_init1 = ;rate of change of ref. gr. [nm/ps] pull_rate1 = 0.0005 ;force constant [KJ mol^-1 nm^-2] pull_k1 = 500 ;pull_kB1 = ; ENERGY GROUP EXCLUSIONS = ; Pairs of energy groups for which all non-bonded interactions are excluded = energygrp_excl = ; NMR refinement stuff = ; Distance restraints type: No, Simple or Ensemble = disre = No ; Force weighting of pairs in one distance restraint: Conservative or Equal = disre-weighting = Conservative ; Use sqrt of the time averaged times the instantaneous violation = disre-mixed = no disre-fc = 1000 disre-tau = 0 ; Output frequency for pair distances to energy file = nstdisreout = 100 ; Orientation restraints: No or Yes = orire = no ; Orientation restraints force constant and tau for time averaging = orire-fc = 0 orire-tau = 0 orire-fitgrp = ; Output frequency for trace(SD) to energy file = nstorireout = 100 ; Free energy control stuff = free-energy = no init-lambda = 0 delta-lambda = 0 sc-alpha = 0 sc-sigma = 0.3 ; Non-equilibrium MD stuff = acc-grps = accelerate = freezegrps = freezedim = cos-acceleration = 0 ; Electric fields = ; Format is number of terms (int) and for all terms an amplitude (real) = ; and a phase angle (real) = E-x = E-xt = E-y = E-yt = E-z = E-zt = ; User defined thingies = user1-grps = user2-grps = userint1 = 0 userint2 = 0 userint3 = 0 userint4 = 0 userreal1 = 0 userreal2 = 0 userreal3 = 0 userreal4 = 0
_______________________________________________ gmx-users mailing list gmx-users@gromacs.org http://www.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org. Can't post? Read http://www.gromacs.org/mailing_lists/users.php